Dtc B1411/11 Room Temperature Sensor Circuit
DESCRIPTION
WIRING DIAGRAM
INSPECTION PROCEDURE
READ VALUE USING INTELLIGENT TESTER (ROOM TEMP)
INSPECT ROOM TEMPERATURE SENSOR
CHECK WIRE HARNESS (ROOM TEMPERATURE SENSOR - AIR CONDITIONING AMPLIFIER)
DTC B1411/11 Room Temperature Sensor Circuit |
DESCRIPTION
The room temperature sensor is installed in the instrument panel to detect the room temperature and control the heater and air conditioner AUTO mode. The resistance of the room temperature sensor changes in accordance with the room temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.The air conditioning amplifier applies a voltage (5 V) to the room temperature sensor and reads voltage changes as changes in the resistance of the room temperature sensor.DTC No.
| DTC Detection Condition
| Trouble Area
|
B1411/11
| Open or short in room temperature sensor circuit
| - Room temperature sensor
- Harness and connector between room temperature sensor and air conditioning amplifier
- Air conditioning amplifier
|
WIRING DIAGRAM
INSPECTION PROCEDURE
1.READ VALUE USING INTELLIGENT TESTER (ROOM TEMP) |
Connect the intelligent tester to the DLC3.
Turn the ignition switch on (IG) and turn the intelligent tester main switch ON.
Select the item below in the Data List, and read the value displayed on the intelligent tester.
- Air conditioning amplifier:
Item
| Measurement Item / Display (Range)
| Normal Condition
| Diagnostic Note
|
Room Temp
| Room temperature sensor / Min.: -6.5°C (20.3°F) Max.: 57.25°C (135.05°F)
| Actual room temperature is displayed
| Open circuit: -6.5°C (20.3°F) Short circuit: 57.25°C (135.05°F)
|
- OK:
- The display is as specified in the normal condition column.
ResultResult
| Proceed to
|
NG
| A
|
OK (Checking from the PROBLEM SYMPTOMS TABLE)
| B
|
OK (Checking from the DTC)
| C
|
| PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE |
|
|
| REPLACE AIR CONDITIONING AMPLIFIER |
|
|
2.INSPECT ROOM TEMPERATURE SENSOR |
Remove the room temperature sensor.
Measure the resistance of the sensor.
- Standard resistance:
Tester Connection
| Condition
| Specified Condition
|
1 (ST+) - 2 (ST-)
| 10°C (50°F)
| 3.00 to 3.73 kΩ
|
1 (ST+) - 2 (ST-)
| 15°C (59°F)
| 2.45 to 2.88 kΩ
|
1 (ST+) - 2 (ST-)
| 20°C (68°F)
| 1.95 to 2.30 kΩ
|
1 (ST+) - 2 (ST-)
| 25°C (77°F)
| 1.60 to 1.80 kΩ
|
1 (ST+) - 2 (ST-)
| 30°C (86°F)
| 1.28 to 1.47 kΩ
|
1 (ST+) - 2 (ST-)
| 35°C (95°F)
| 1.00 to 1.22 kΩ
|
1 (ST+) - 2 (ST-)
| 40°C (104°F)
| 0.80 to 1.00 kΩ
|
1 (ST+) - 2 (ST-)
| 45°C (113°F)
| 0.65 to 0.85 kΩ
|
1 (ST+) - 2 (ST-)
| 50°C (122°F)
| 0.50 to 0.70 kΩ
|
1 (ST+) - 2 (ST-)
| 55°C (131°F)
| 0.44 to 0.60 kΩ
|
1 (ST+) - 2 (ST-)
| 60°C (140°F)
| 0.36 to 0.50 kΩ
|
- NOTICE:
- Touching the sensor even slightly may change the resistance value. Be sure to hold the connector of the sensor.
- When measuring, the sensor temperature must be the same as the ambient temperature.
- HINT:
- As the temperature increases, the resistance decreases (see the graph).
| REPLACE ROOM TEMPERATURE SENSOR |
|
|
3.CHECK WIRE HARNESS (ROOM TEMPERATURE SENSOR - AIR CONDITIONING AMPLIFIER) |
Disconnect the E24 sensor connector.
Disconnect the E41 amplifier connector.
Measure the resistance of the wire harness side connectors.
- Standard resistance:
Tester Connection
| Specified Condition
|
E24-1 (ST+) - E41-29 (TR)
| Below 1 Ω
|
E24-2 (ST-) - E41-34 (SG-1)
| Below 1 Ω
|
E24-1 (ST+) - Body ground
| 1 MΩ or higher
|
E24-2 (ST-) - Body ground
| 1 MΩ or higher
|
| REPAIR OR REPLACE HARNESS AND CONNECTOR |
|
|
OK |
|
|
|
REPLACE AIR CONDITIONING AMPLIFIER |
|