Air Conditioning System (For Manual Air Conditioning System) Blower Motor Circuit
DESCRIPTION
WIRING DIAGRAM
INSPECTION PROCEDURE
INSPECT FUSE (HTR)
INSPECT HEATER RELAY (Marking: HTR)
INSPECT BLOWER MOTOR
CHECK WIRE HARNESS (HEATER CONTROL (BLOWER SWITCH) - BATTERY)
INSPECT HEATER CONTROL (BLOWER SWITCH)
INSPECT BLOWER RESISTOR
CHECK WIRE HARNESS (HEATER CONTROL (BLOWER SWITCH) - BLOWER RESISTOR)
CHECK WIRE HARNESS (BLOWER RESISTOR - BLOWER MOTOR)
CHECK WIRE HARNESS (BLOWER MOTOR - BODY GROUND)
CHECK WIRE HARNESS (AIR CONDITIONING AMPLIFIER - BATTERY)
CHECK WIRE HARNESS (AIR CONDITIONING AMPLIFIER - BODY GROUND)
AIR CONDITIONING SYSTEM (for Manual Air Conditioning System) - Blower Motor Circuit |
DESCRIPTION
When the heater control (blower switch) is set to position 1 or higher, the contact of the HTR relay is closed, current flows to the blower motor, and the blower motor operates. The blower motor speed can be changed by exchanging the ground and the blower resistor circuit with the heater control (blower switch).
WIRING DIAGRAM
INSPECTION PROCEDURE
Remove the HTR fuse from the engine room No. 2 relay block.
Measure the resistance of the fuse.
- Standard resistance:
- Below 1 Ω
2.INSPECT HEATER RELAY (Marking: HTR) |
Remove the heater relay from the instrument panel junction block.
Measure the resistance of the relay.
- Standard resistance:
Tester Connection
| Specified Condition
|
3 - 4
| Below 1 Ω
|
3 - 5
| 10 kΩ or higher
|
3 - 4
| 10 kΩ or higher (when battery voltage is applied to terminals 1 and 2)
|
3 - 5
| Below 1 Ω (when battery voltage is applied to terminals 1 and 2)
|
Disconnect the E61 motor connector.
Connect the positive (+) lead from the battery to terminal 2 and the negative (-) lead to terminal 1, then check that the blower motor operates smoothly.
- OK:
- The blower motor operates smoothly.
Measure the current.
- Standard current:
Tester Connection
| Condition
| Specified Condition
|
E61-1 - E61-2
| Blower motor operates
| 1 to 3 A
|
4.CHECK WIRE HARNESS (HEATER CONTROL (BLOWER SWITCH) - BATTERY) |
Disconnect the E27 heater control connector.
Measure the voltage of the wire harness side connector.
- Standard voltage:
Tester Connection
| Condition
| Specified Condition
|
E27-4 (LO) - Body ground
| Ignition switch on (IG)
| 10 to 14 V
|
| REPAIR OR REPLACE HARNESS AND CONNECTOR |
|
|
5.INSPECT HEATER CONTROL (BLOWER SWITCH) |
Remove the heater control.
Measure the resistance of the switch.
- Standard resistance:
Tester Connection
| Switch Position
| Specified Condition
|
ALL - 5 (E)
| 0
| 10 kΩ or higher
|
4 (LO) - 5 (E)
| 1
| Below 1 Ω
|
4 (LO) - 5 (E) - 9 (M1)
| 1 to 2
| Below 1 Ω
|
4 (LO) - 5 (E) - 9 (M1)
| 2
| Below 1 Ω
|
4 (LO) - 5 (E) - 9 (M1) - 10 (M2)
| 2 to 3
| Below 1 Ω
|
4 (LO) - 5 (E) - 10 (M2)
| 3
| Below 1 Ω
|
4 (LO) - 5 (E) - 10 (M2) - 6(HI)
| 3 to 4
| Below 1 Ω
|
4 (LO) - 5 (E) - 6 (HI)
| 4
| Below 1 Ω
|
6.INSPECT BLOWER RESISTOR |
Remove the blower resistor.
Measure the resistance of the resistor.
- Standard resistance:
- for LHD
Tester Connection
| Specified Condition
|
E62-4 (E) - E62-1 (HI)
| 3.12 to 3.60 Ω
|
E62-4 (E) - E62-3 (M2)
| 1.45 to 1.67 Ω
|
E62-4 (E) - E62-2 (M1)
| 0.52 to 0.60 Ω
|
- for RHD
Tester Connection
| Specified Condition
|
E62-1 (E) - E62-4 (HI)
| 3.12 to 3.60 Ω
|
E62-1 (E) - E62-2 (M2)
| 1.45 to 1.67 Ω
|
E62-1 (E) - E62-3 (M1)
| 0.52 to 0.60 Ω
|
7.CHECK WIRE HARNESS (HEATER CONTROL (BLOWER SWITCH) - BLOWER RESISTOR) |
Disconnect the E27 heater control connector.
Disconnect the E62 blower resistor connector.
Measure the resistance of the wire harness side connectors.
- Standard resistance:
- for LHD
Tester Connection
| Specified Condition
|
E27-6 (HI) - E62-1 (HI)
| Below 1 Ω
|
E27-9 (M1) - E62-2 (M1)
| Below 1 Ω
|
E27-10 (M2) - E62-3 (M2)
| Below 1 Ω
|
E27-5 (E) - Body ground
| Below 1 Ω
|
E62-4 (E) - Body ground
| Below 1 Ω
|
- for RHD
Tester Connection
| Specified Condition
|
E27-6 (HI) - E62-4 (HI)
| Below 1 Ω
|
E27-9 (M1) - E62-3 (M1)
| Below 1 Ω
|
E27-10 (M2) - E62-2 (M2)
| Below 1 Ω
|
E27-5 (E) - Body ground
| Below 1 Ω
|
E62-1 (E) - Body ground
| Below 1 Ω
|
| REPAIR OR REPLACE HARNESS AND CONNECTOR |
|
|
8.CHECK WIRE HARNESS (BLOWER RESISTOR - BLOWER MOTOR) |
Disconnect the E62 blower resistor connector.
Disconnect the E61 motor connector.
Measure the resistance of the wire harness side connectors.
- Standard resistance:
- for LHD
Tester Connection
| Specified Condition
|
E62-4 (E) - E61-1
| Below 1 Ω
|
- for RHD
Tester Connection
| Specified Condition
|
E62-1 (E) - E61-1
| Below 1 Ω
|
| REPAIR OR REPLACE HARNESS AND CONNECTOR |
|
|
9.CHECK WIRE HARNESS (BLOWER MOTOR - BODY GROUND) |
Disconnect the E61 motor connector.
Measure the resistance of the wire harness side connector.
- Standard resistance:
Tester Connection
| Specified Condition
|
E61-2 - Body ground
| Below 1 Ω
|
Measure the voltage of the wire harness side connector.
- Standard voltage:
Tester Connection
| Condition
| Specified Condition
|
E61-2 - Body ground
| Ignition switch on (IG) Heater control (blower switch) 1
| 10 to 14 V
|
| REPAIR OR REPLACE HARNESS AND CONNECTOR |
|
|
10.CHECK WIRE HARNESS (AIR CONDITIONING AMPLIFIER - BATTERY) |
Disconnect the E42 amplifier connector.
Measure the voltage of the wire harness side connector.
- Standard voltage:
Tester Connection
| Condition
| Specified Condition
|
E42-21 (SBLW) - Body ground
| Ignition switch on (IG) Heater control (blower switch): 0
| 10 to 14 V
|
| REPAIR OR REPLACE HARNESS AND CONNECTOR |
|
|
11.CHECK WIRE HARNESS (AIR CONDITIONING AMPLIFIER - BODY GROUND) |
Disconnect the E42 amplifier connector.
Measure the resistance of the wire harness side connector.
- Standard resistance:
Tester Connection
| Specified Condition
|
E42-24 (GND) - Body ground
| Below 1 Ω
|
| REPAIR OR REPLACE HARNESS AND CONNECTOR |
|
|
OK |
|
|
|
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE |
|