Ecm -- Removal |
1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL |
- CAUTION:
- Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to prevent airbag and seat belt pretensioner activation.
2. REMOVE AIR CLEANER CAP |
Disconnect the mass air flow meter connector.
![]() |
Disconnect the purge VSV connector.
Disconnect the 4 wire harness clamps.
Disconnect the No. 2 ventilation hose from the air cleaner hose.
![]() |
Disconnect the purge line hose from the clamp.
Lock the No. 1 air cleaner hose clamp, and then disconnect the No. 1 air cleaner hose from the throttle body.
![]() |
Unfasten the 2 hook clamps, and then remove the air cleaner cap.
![]() |
Remove the air cleaner filter element from the air cleaner case.
3. REMOVE AIR CLEANER CASE |
Disconnect the harness clamp.
![]() |
Remove the 3 bolts and air cleaner case.
4. REMOVE ECM |
Remove the 3 bolts of the ECM with brackets.
![]() |
Disconnect the 2 ECM connectors.
- NOTICE:
- After disconnecting the connector, make sure that dirt, water and other foreign matter does not contact the connecting part of the connector.
Raise the 2 levers while pushing the locks on the 2 levers, and disconnect the 2 ECM connectors.
![]() |
Remove the ECM with brackets.
Remove the 4 screws and 2 ECM brackets.
![]() |