Dtc P0982 Shift Solenoid D Control Circuit Low (Shift Solenoid Valve S4)
DESCRIPTION
MONITOR DESCRIPTION
WIRING DIAGRAM
INSPECTION PROCEDURE
INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE S4)
CHECK WIRE HARNESS (TRANSMISSION WIRE - ECM)
INSPECT SHIFT SOLENOID VALVE S4
DTC P0982 Shift Solenoid "D" Control Circuit Low (Shift Solenoid Valve S4) |
DTC P0983 Shift Solenoid "D" Control Circuit High (Shift Solenoid Valve S4) |
DESCRIPTION
Shifting from 1st to O/D is performed in combination with the ON and OFF operation of the shift solenoid valves SL1 and SL2, which are controlled by the ECM. If an open or short circuit occurs in any of the shift solenoid valves, the ECM controls the remaining normal shift solenoid valves to allow the vehicle to be operated safely (RAV4_ACA30 RM000000O8L0BEX.html).DTC No.
| DTC Detection Condition
| Trouble Area
|
P0982
| ECM detects short in solenoid valve S4 circuit 2 times when solenoid valve S4 is operated (1 trip detection logic)
| - Short in shift solenoid valve S4 circuit
- Shift solenoid valve S4
- ECM
|
P0983
| ECM detects open in solenoid valve S4 circuit 2 times when solenoid valve S4 is not operated (1 trip detection logic)
| - Open in shift solenoid valve S4 circuit
- Shift solenoid valve S4
- ECM
|
MONITOR DESCRIPTION
This DTC indicates an open or short in the shift solenoid valve S4 circuit. The ECM commands gear shifts by turning the shift solenoid valves ON/OFF. When there is an open or short circuit in any shift solenoid valve circuit, the ECM detects the problem, illuminates the MIL and stores the DTC. Also, the ECM performs the fail-safe function and turns the other normal shift solenoid valves ON/OFF. In case of an open or short circuit, the ECM stops sending current to the circuit (RAV4_ACA30 RM000000O8L0BEX.html).
WIRING DIAGRAM
INSPECTION PROCEDURE
1.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE S4) |
Disconnect the B29 wire connector.
Measure the resistance of the transmission wire.
- Standard resistance:
Tester Connection
| Condition
| Specified Condition
|
8 (S4) - Body ground
| 20°C (68°F)
| 11 to 15 Ω
|
2.CHECK WIRE HARNESS (TRANSMISSION WIRE - ECM) |
Connect the B29 wire connector.
Disconnect the B32 ECM connector.
Measure the resistance of the wire harness side connector.
- Standard resistance:
Tester Connection
| Condition
| Specified Condition
|
B32-78 (S4) - Body ground
| 20°C (68°F)
| 11 to 15 Ω
|
| REPAIR OR REPLACE HARNESS AND CONNECTOR |
|
|
3.INSPECT SHIFT SOLENOID VALVE S4 |
Remove the shift solenoid valve S4.
Measure the resistance of the solenoid valve.
- Standard resistance:
- 11 to 15 Ω at 20°C (68°F)
Connect the battery's positive (+) lead to the terminal of the solenoid valve connector, and the negative (-) lead to the solenoid body. Then check that the valve moves and makes an operating noise.
- OK:
- Valve moves and makes operating noise.
| REPLACE SHIFT SOLENOID VALVE S4 |
|
|
OK |
|
|
|
REPAIR OR REPLACE TRANSMISSION WIRE |
|