Heater & Air Conditioning System. Toyota Rav4. Aca30, 33, 38 Gsa33 Zsa30, 35
Air Conditioning. Toyota Rav4. Aca30, 33, 38 Gsa33 Zsa30, 35
Air Conditioning System (For Automatic Air Conditioning System) -- Data List / Active Test |
READ DATA LIST |
![]() |
- HINT:
- Using the intelligent tester's Data List allows switch, sensor, actuator and other item values to be read without removing any parts. Reading the Data List early in troubleshooting is one way to save time.
Connect the intelligent tester to the DLC3.
Turn the ignition switch on (IG) and turn the intelligent tester ON.
Read the Data List by following the prompts on the tester.
Air conditioning amplifier Tester Display Measurement Item/Range Normal Condition Diagnostic Note Room Temperature Sensor Room temperature sensor /
Min.: -6.5°C (20.3°F)
Max.: 57.25°C (135.05°F)Actual room temperature is displayed Open circuit: -6.5°C (20.3°F)
Short circuit: 57.25°C (135.05°F)Ambient Temp Sensor Ambient temperature sensor /
Min.: -23.3°C (-9.94°F)
Max.: 65.95°C (150.71°F)Actual ambient temperature is displayed Open circuit: -23.3°C (-9.94°F)
Short circuit: 65.95°C (150.71°F)Adjusted Ambient Temp Adjusted ambient temperature /
Min.: -30.8°C (-23.44°F)
Max.: 50.8°C (123.44°F)- - Evaporator Fin Thermistor Evaporator temperature sensor /
Min.: -29.7°C (-21.46°F)
Max.: 59.55°C (139.19°F)Actual evaporator temperature is displayed Open circuit: -29.7°C (-21.46°F)
Short circuit: 59.55°C (139.19°F)Solar Sensor (D side) Driver side solar sensor /
Min.: 0, Max.: 255Driver side solar sensor value increases as brightness increases - Solar Sensor (P side) Passenger side solar sensor /
Min.: 0, Max.: 255Passenger side solar sensor value increases as brightness increases - Engine Coolant Temp Engine coolant temperature /
Min.: 1.3°C (34.34°F)
Max.: 90.55°C (194.99°F)Actual engine coolant temperature is displayed after engine warmed up - Set Temperature (D side) Driver side set temperature /
Min.: 0°C (32°F)
Max.: 30°C (54°F)Driver side actual set temperature is displayed - Set Temperature (P side) Passenger side set temperature /
Min.: 0°C (32°F)
Max.: 30°C (54°F)Passenger side actual set temperature is displayed - Blower Motor Speed Level Blower motor speed level /
Min.: 0 level, Max.: 31 levelIncreases 0 to 31 as blower motor speed increases - Regulator Pressure Sensor Regulator pressure sensor /
Min.: -0.45668 MPaG
Max.: 3.29437 MPaGActual regulator pressure is displayed - Regulator Control Current Regulator control current /
Min.: 0 A
Max.: 0.997 AValue changes between 0 A and 0.997 A in accordance with compressor operation - Air Mix Servo Targ Pulse (D) Driver side air mix servo motor target pulse /
Min.: 0, Max.: 255LHD:
MAX. COLD: 92 (pulse)
MAX. HOT: 5 (pulse)
RHD:
MAX. COLD: 6 (pulse)
MAX. HOT: 93 (pulse)- Air Mix Servo Targ Pulse (P) Passenger side air mix servo motor target pulse /
Min.: 0, Max.: 255LHD:
MAX. COLD: 6 (pulse)
MAX. HOT: 93 (pulse)
RHD:
MAX. COLD: 92 (pulse)
MAX. HOT: 5 (pulse)- Air Outlet Servo Pulse (D) Air outlet servo motor target /
Min.: 0, Max.: 255FACE: 47 (pulse)
B/L: 37 (pulse)
FOOT: 17 (pulse)
FOOT/DEF: 9 (pulse)
DEF: 5 (pulse)- Air Inlet Damper Targ Pulse Air inlet damper target pulse /
Min.: 0, Max.: 255LHD:
RECIRCULATION: 19 (pulse)
FRESH: 7 (pulse)
RHD:
RECIRCULATION: 7 (pulse)
FRESH: 25 (pulse)- Electric Heater Count Electric (PTC) heater count /
Min.: 0
Max.: 3Actual number of the heater elements to be heated is displayed - Shift Set Temperature Shift set temperature / +2 C, +1 C, NORMAL, -1 C, -2 C Customized value displayed - Air Inlet Mode Air inlet mode /
AUTO, MANUALCustomized value displayed - Compressor Mode Compressor mode /
AUTO, MANUALCustomized value displayed - Compressor/DEF Mode Compressor / DEF Mode /
LINK, NORMALCustomized value displayed - Evaporator Control Evaporator Control /
AUTO, MANUALCustomized value displayed - Foot/DEF Auto Mode Foot / DEF auto mode /
ON, OFFCustomized value displayed - Foot/DEF Auto Blow Up Foot / DEF automatic blow up function /
ON, OFFCustomized value displayed - Ambient Temperature Shift Ambient temperature shift / +3C, +2C, +1C, Normal, -1C, -2C, -3C Customized value displayed - Number of Trouble Codes Number of trouble codes /
Min.: 0, Max.: 255Number of DTCs displayed -
PERFORM ACTIVE TEST |
- HINT:
- Performing the intelligent tester's Active Test allows relays, the VSV, actuators and other items to be operated without removing any parts. Performing the Active Test early in troubleshooting is one way to save time. The Data List can be displayed in the Active Test.
Connect the intelligent tester to the DLC3.
Turn the ignition switch on (IG) and turn the intelligent tester ON.
Perform the Active Test by following the prompts on the tester.
Air conditioning amplifier Tester Display Test Part Control Range Diagnostic Note Blower Motor Blower motor Min.: 0, Max.: 31 - Magnetic Clutch Relay Magnetic clutch relay OFF, ON - Defogger Relay (Rear) Defogger relay (Rear) OFF, ON - Electric Heater 1 PTC heater No. 1 relay OFF, ON - Electric Heater 2 PTC heater No. 2 relay OFF, ON - Air Mix Servo Targ Pulse (D) Air mix servo motor pulse Min.: 0, Max.: 255 - Air Mix Servo Targ Pulse (P) Air mix servo motor pulse (P side) Min.: 0, Max.: 255 - Air Outlet Servo Pulse (D) Air outlet servo motor pulse Min.: 0, Max.: 255 - Air Inlet Damper Targ Pulse Air inlet damper target pulse Min.: 0, Max.: 255 -