Compressor And Magnetic Clutch Inspection

Heater & Air Conditioning System. Lexus Is250, Is220D. Gse20 Ale20
Air Conditioning. Lexus Is250, Is220D. Gse20 Ale20

  1. INSPECT A/C COMPRESSOR

  2. INSPECT MAGNETIC CLUTCH

  3. INSPECT A/C COMPRESSOR (LOCK SENSOR)

  4. INSPECT A/C COMPRESSOR (SOLENOID)

Compressor And Magnetic Clutch -- Inspection



1. INSPECT A/C COMPRESSOR


    Lexus Is250, Is220D. Gse20 Ale20.Air Conditioning.Air Conditioning System.Compressor And Magnetic Clutch  Inspection
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    E8-1 (MG+) - A-1
    Always
    Below 1 Ω
    E8-1 (MG;) - Body ground
    Always
    10 kΩ or higher
    If the resistance is not as specified, replace the A/C compressor.


2. INSPECT MAGNETIC CLUTCH


    Lexus Is250, Is220D. Gse20 Ale20.Air Conditioning.Air Conditioning System.Compressor And Magnetic Clutch  Inspection
  1. Measure the resistance of the connector.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    A-1 - Body ground
    Always
    3.4 to 3.8 Ω
    If the resistance is not as specified, replace the magnetic clutch.
  1. When connector terminal A1 is connected to the positive (+) battery terminal, check that the following occurs: 1) the magnetic clutch's operating sound can be heard, and 2) the magnetic clutch's hub and rotor lock.



3. INSPECT A/C COMPRESSOR (LOCK SENSOR)


    Lexus Is250, Is220D. Gse20 Ale20.Air Conditioning.Air Conditioning System.Compressor And Magnetic Clutch  Inspection
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Specified Condition
    E8-2 (SSR+) - E8-5 (SSR-)
    160 to 320 Ω
    If the resistance is not as specified, replace the A/C compressor.


4. INSPECT A/C COMPRESSOR (SOLENOID)


    Lexus Is250, Is220D. Gse20 Ale20.Air Conditioning.Air Conditioning System.Compressor And Magnetic Clutch  Inspection
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    E8-3 (SOL+) - E8-6 (SOL-)
    20°C (68°F)
    10 to 11 Ω