Body Electrical. Lexus Is250, Is220D. Gse20 Ale20
Meter. Lexus Is250, Is220D. Gse20 Ale20
Light Control Rheostat -- Inspection |
1. INSPECT LIGHT CONTROL RHEOSTAT |
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection Condition Specified Condition E (J15-1) - RV (J15-4) Light control rheostat position is MIN. Below 1 Ω E (J15-1) - RV (J15-4) Light control rheostat position is between MIN. and MAX. 8 to 12 kΩ E (J15-1) - RV (J15-4) ODO/TRIP switch is OFF 10 kΩ or higher ODO/TRIP switch is ON Below 1 Ω T (J15-2) - TC (J15-3) Rheostat knob is in the MIN. position Below 1 Ω T (J15-2) - TC (J15-3) Rheostat knob is in the MAX. position 10 kΩ or higher
- HINT:
- If the value is not as specified, replace the light control rheostat.
![]() |