Steering. Lexus Is250, Is220D. Gse20 Ale20
Power Steering. Lexus Is250, Is220D. Gse20 Ale20
Electronic Power Steering System -- Data List / Active Test |
DATA LIST |
- HINT:
- By accessing the Data List displayed on the intelligent tester, values of switches, sensors and other related parts can be checked without removing any parts. Reading the Data List is the first step of troubleshooting and is one method to shorten labor time.
Connect the intelligent tester to the DLC3.
Turn the engine switch on (IG).
Operate the intelligent tester according to the steps on the display and select the Data List.
Item Item Description/Range (Display) Inspection Condition Reference Value Trq1 Torque sensor 1 rotation angle/
Min.: 0 deg, Max.: 360 degSteering wheel is turned Value changes from 0 to 360° every 22.5° of steering angle Trq2 Torque sensor 2 rotation angle/
Min.: 0 deg, Max.: 360 degSteering wheel is turned Value changes from 0 to 360° every 22.5° of steering angle Engine Speed Vehicle speed from meter/
Min.: 0 km/h (0 mph), Max.: 255 km/h (158 mph)- Vehicle is stopped
- Vehicle is driven at a constant speed
- 0 km/h (0 mph)
- No significant fluctuation
Engine Rev Engine revolution/
Min.: 0 rpm, Max.: 8,192 rpmEngine is running at a constant speed No significant fluctuation Motor Actual Amount of current to motor/
Min.: -128 A, Max.: 127 APower steering is in operation Value changes in proportion to steering effort Command Value Demanded amount of current to motor/
Min.: -128 A, Max.: 127 APower steering is in operation Value changes in proportion to steering effort Str Angl Vel Steering angle speed/
Min.: -4,096 deg/sec, Max.: 4,064 deg/secSteering wheel is turned Value changes in proportion to steering speed Thermistor Temp ECU substrate temperature/
Min.: -50°C, Max.: 205°CEngine switch on (IG) - PIG Supply Power source voltage to activate motor/
Min.: 0 V, Max.: 25.5 VPower steering is in operation 10 to 14 V IG Supply ECU power source voltage/
Min.: 0 V, Max.: 25.5 VEngine switch on (IG) 10 to 14 V Trq1 Zero Val Zero point value of torque sensor 1/
Min.: 0 deg, Max.: 360 degSteering wheel is not turned
(without load)Values differ depending on vehicle Trq2 Zero Val Zero point value of torque sensor 2/
Min.: 0 deg, Max.: 360 degSteering wheel is not turned
(without load)Values differ depending on vehicle Steering Torque Steering torque/
Min.: -7.0 N*m, Max.: 7.0 N*mSteering wheel is turned Value changes in proportion to steering effort Motor Rotate Motor rotation angle/
Min.: 0 deg, Max.: 360 degSteering wheel is turned Value changes from 0 to 360° every 5° of steering angle Command Value 2 Amount of current demanded by motor 2/
Min.: -128 A, Max.: 127 A- - PIG2 Voltage Motor drive voltage after pressurization Power steering is in operation 27 to 34 V Motor Voltage Motor power source voltage/
Min.: 0 V, Max.: 64 VPower steering is in operation 27 to 34 V Mtr Terminal (U) Motor terminal voltage (U phase)/
Min.: 0 V, Max.: 64 VPower steering is in operation 0 to 34 V Mtr Terminal (V) Motor terminal voltage (V phase)/
Min.: 0 V, Max.: 64 VPower steering is in operation 0 to 34 V Mtr Terminal (W) Motor terminal voltage (W phase)/
Min.: 0 V, Max.: 64 VPower steering is in operation 0 to 34 V Str Sens Sig Steering angle sensor signal status/
OK or NG- - Mtr Overheat Continuous overheat prevention control record/
REC or UNREC- - Mtr Low Power PIG power source voltage drop record/
REC or UNREC- - Eng Rev Inter Record of engine revolution signal interruption/
REC or UNREC- - Str Angl Inter Record of steering angle sensor signal interruption/
REC or UNREC- - Spd Sig Invalid Record of vehicle speed signal invalid/
REC or UNREC- - IG ON/OFF Times Number of times IG switch is turned on after DTC detection/
Min.: 0 time, Max.: 255 times- - DTC Number of detected DTCs when freeze frame data is stored/
Min.: 0, Max.: 255- - Battery Voltage BATTERY VOLTAGE
Min.: 0V, Max.: 25.5- 10 to 14 V PS Assist Sig Power steering assist signal/
ON or OFFEngine switch on (IG) - - Vehicle is stopped