Shift Solenoid Valve Inspection

Transmission. Lexus Is250, Is220D. Gse20 Ale20
A960E Automatic Transmission. Lexus Is250, Is220D. Gse20 Ale20

  1. INSPECT SHIFT SOLENOID VALVE SL1

  2. INSPECT SHIFT SOLENOID VALVE S1

  3. INSPECT SHIFT SOLENOID VALVE S2

  4. INSPECT SHIFT SOLENOID VALVE S3

  5. INSPECT SHIFT SOLENOID VALVE S4

  6. INSPECT SHIFT SOLENOID VALVE SL2

  7. INSPECT SHIFT SOLENOID VALVE SR

  8. INSPECT SHIFT SOLENOID VALVE SLT

  9. INSPECT SHIFT SOLENOID VALVE SLU

Shift Solenoid Valve -- Inspection



1. INSPECT SHIFT SOLENOID VALVE SL1


    Lexus Is250, Is220D. Gse20 Ale20.A960E Automatic Transmission.Automatic Transmission System.Shift Solenoid Valve  Inspection
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Specified Condition
    20°C (68°F)
    1 - 2
    5.0 to 5.6 Ω
  1. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the operation of the valve.

    OK:
    The solenoid makes an operating sound.
    If the resistance is not within the specified range, replace the shift solenoid valve SL1.


2. INSPECT SHIFT SOLENOID VALVE S1


    Lexus Is250, Is220D. Gse20 Ale20.A960E Automatic Transmission.Automatic Transmission System.Shift Solenoid Valve  Inspection
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Specified Condition
    20°C (68°F)
    Solenoid Connector (S1) - Solenoid Body (S1)
    11 to 15 Ω
  1. Connect the positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body, then check the operation of the valve.

    OK:
    The solenoid makes an operating sound.
    If the resistance is not within the specified range, replace the shift solenoid valve S1.


3. INSPECT SHIFT SOLENOID VALVE S2


    Lexus Is250, Is220D. Gse20 Ale20.A960E Automatic Transmission.Automatic Transmission System.Shift Solenoid Valve  Inspection
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Specified Condition
    20°C (68°F)
    Solenoid Connector (S2) - Solenoid Body (S2)
    11 to 15 Ω
  1. Connect the positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body.

    OK:
    The solenoid makes an operating noise.
    If the resistance is not within the specified range, replace the shift solenoid valve S2.


4. INSPECT SHIFT SOLENOID VALVE S3


    Lexus Is250, Is220D. Gse20 Ale20.A960E Automatic Transmission.Automatic Transmission System.Shift Solenoid Valve  Inspection
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Specified Condition
    20°C (68°F)
    Solenoid Connector (S3) - Solenoid Body (S3)
    11 to 15 Ω
  1. Connect the positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body, then check the operation of the valve.

    OK:
    The solenoid makes an operating sound.
    If the resistance is not within the specified range, replace the shift solenoid valve S3.


5. INSPECT SHIFT SOLENOID VALVE S4


    Lexus Is250, Is220D. Gse20 Ale20.A960E Automatic Transmission.Automatic Transmission System.Shift Solenoid Valve  Inspection
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Specified Condition
    20°C (68°F)
    Solenoid Connector (S4) - Solenoid Body (S4)
    11 to 15 Ω
  1. Connect the positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body.

    OK:
    The solenoid makes an operating sound.
    If the resistance is not within the specified range, replace the shift solenoid valve S4.


6. INSPECT SHIFT SOLENOID VALVE SL2


    Lexus Is250, Is220D. Gse20 Ale20.A960E Automatic Transmission.Automatic Transmission System.Shift Solenoid Valve  Inspection
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Specified Condition
    20°C (68°F)
    1 - 2
    5.0 to 5.6 Ω
  1. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the operation of the valve.

    OK:
    The solenoid makes an operating sound.
    If the resistance is not within the specified range, replace the shift solenoid valve SL2.


7. INSPECT SHIFT SOLENOID VALVE SR


    Lexus Is250, Is220D. Gse20 Ale20.A960E Automatic Transmission.Automatic Transmission System.Shift Solenoid Valve  Inspection
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Specified Condition
    20°C (68°F)
    Solenoid Connector (SR) - Solenoid Body (SR)
    11 to 15 Ω
  1. Connect the positive (+) lead to the terminal of the solenoid valve connector, and the negative (-) lead to the solenoid body, then check the operation of the valve.

    OK:
    The solenoid makes an operating sound.
    If the resistance is not within the specified range, replace the shift solenoid valve SR.


8. INSPECT SHIFT SOLENOID VALVE SLT


    Lexus Is250, Is220D. Gse20 Ale20.A960E Automatic Transmission.Automatic Transmission System.Shift Solenoid Valve  Inspection
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Specified Condition
    20°C (68°F)
    1 - 2
    5.0 to 5.6 Ω
  1. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the operation of the valve.

    OK:
    The solenoid makes an operating sound.
    If the resistance is not within the specified range, replace the shift solenoid valve SLT.


9. INSPECT SHIFT SOLENOID VALVE SLU


    Lexus Is250, Is220D. Gse20 Ale20.A960E Automatic Transmission.Automatic Transmission System.Shift Solenoid Valve  Inspection
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Specified Condition
    20°C (68°F)
    1 - 2
    5.0 to 5.6 Ω
  1. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the operation of the valve.

    OK:
    The solenoid makes an operating sound.
    If the resistance is not within the specified range, replace the shift solenoid valve SLU.