Steering. Lexus Gs430, Gs300. Uzs190 Grs190
Steering Column. Lexus Gs430, Gs300. Uzs190 Grs190
Variable Gear Ratio Steering System -- Freeze Frame Data |
- HINT:
- The VGRS system stores data when a trouble code is set and can be viewed using the intelligent tester.
FREEZE FRAME DATA OF STEERING CONTROL ECU |
Connect the intelligent tester to the DLC3.
Turn the engine switch on (IG) and turn the intelligent tester on.
Select "FREEZE FRAME DATA" from the display on the tester.
Intelligent Tester Display Measurement Item Value (Unit) Vehicle Speed(Vsc ECU) Vehicle speed (VSC ECU) Speed indicated on speedometer (km/h) Engine ReVolution(Rpm) Engine revolution (rpm) Less than 300 or more then 300 (rpm) Mtr Power Source Cur. Motor power source actual current 0 to 127.5 (A) PIG-Power Source Volt PIG power source voltage 0 to 25.5 (V) IG-Power Source Volt IG power source voltage 0 to 25.5 (V) Lock Motor Output Volt LOCK motor output voltage 0 to 25.5 (V) Command Value Duty Command value DUTY for PVM control 0 to 100 (%) Actuator Lock Duty Val Command value DUTY for actuator lock control 0 to 100 (%) Resolver Offset (SIN) Resolver offset (SIN) 0 to 25.5 (V) Resolver Offset (COS) Resolver offset (COS) 0 to 25.5 (V) Motor Current U Motor current U -63 to 64.5 (A) Motor Current V Motor current V -63 to 64.5 (A) Motor Current W Motor current W -63 to 64.5 (A) Motor Voltage Motor power supply voltage 0 to 51 (V) Steering Pos1 Steering position1 -2047 to 2048.9375 (deg) Actuator Position Actuator position -2047 to 2048.9375 (deg) Steering Angle Velocity Steering wheel angle velocity -2047 to 2048.9375 (deg/sec) Actuator Target Angle1 Actuator target angle1 -2047 to 2048.9375 (deg) Actuator Target Angle2 Actuator target angle2 -2047 to 2048.9375 (deg) Actuator ReVolution Spd Actuator revolution speed -2047 to 2048.9375 (deg)