Dtc P0985 Shift Solenoid E Control Circuit Low (Shift Solenoid Valve Sr)

Transmission. Lexus Gs430, Gs300. Uzs190 Grs190
A761E Automatic Transmission. Lexus Gs430, Gs300. Uzs190 Grs190

DESCRIPTION

MONITOR DESCRIPTION

WIRING DIAGRAM

INSPECTION PROCEDURE

INSPECT TRANSMISSION WIRE (SR)

CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)

INSPECT SHIFT SOLENOID VALVE SR

DTC P0985 Shift Solenoid "E" Control Circuit Low (Shift Solenoid Valve SR)

DTC P0986 Shift Solenoid "E" Control Circuit High (Shift Solenoid Valve SR)


DESCRIPTION

Shifting from 1st to 6th is performed in combination with "ON" and "OFF" operation of the shift solenoid valves SL1, SL2, S1, S2, S3, S4 and SR which is controlled by the ECM. If an open or short circuit occurs in either of the shift solenoid valves, the ECM controls the remaining normal shift solenoid valve to allow the vehicle to be operated smoothly. (In case of an open or short circuit, the ECM stops sending current to the circuit.) Fail safe function (Click here).

DTC No.
DTC Detection Condition
Trouble Area
P0985
ECM detects short in solenoid valve SR circuit 2 times when solenoid valve SR is operated (1-trip detection logic)
  1. Short in shift solenoid valve SR circuit
  2. Shift solenoid valve SR
  3. ECM
P0986
ECM detects open in solenoid valve SR circuit 2 times when solenoid valve SR is not operated (1-trip detection logic)
  1. Open in shift solenoid valve SR circuit
  2. Shift solenoid valve SR
  3. ECM

MONITOR DESCRIPTION

These DTCs indicate an open or short in the shift solenoid valve SR circuit. When there is an open or short circuit in any shift solenoid valve circuit, the ECM detects the problem and illuminates the MIL and stores the DTC. When the shift solenoid valve SR is on, if resistance is 8 Ω or less, the ECM determines there is a short in the shift solenoid valve SR circuit.
When the shift solenoid valve SR is off, if resistance is 100 kΩ or more, the ECM determines there is an open in the shift solenoid valve SR circuit (Click here).

WIRING DIAGRAM


Lexus Gs430, Gs300. Uzs190 Grs190.A761E Automatic Transmission.Electronic Controlled Automatic Transmission System.
Dtc
  P0985  Shift Solenoid E Control Circuit Low (Shift Solenoid Valve Sr)


INSPECTION PROCEDURE

HINT:
  1. The shift solenoid valve SR is turned on/off normally when the shift lever is in the D position:

    ECM command gearshift
    1st
    2nd
    3rd
    4th
    5th
    6th
    Shift solenoid valve SR
    ON
    ON
    ON
    ON
    OFF
    OFF
1.INSPECT TRANSMISSION WIRE (SR)


    Lexus Gs430, Gs300. Uzs190 Grs190.A761E Automatic Transmission.Electronic Controlled Automatic Transmission System.
Dtc
  P0985  Shift Solenoid E Control Circuit Low (Shift Solenoid Valve Sr)
  1. Disconnect the transmission wire connector from the transmission.

  1. Measure the resistance according to the value(s) in the table below.

    Resistance:
    Tester Connection
    Specified Condition
    20°C (68°F)
    6 - Body ground
    11 to 15 Ω


NG
Go to step 3
OK


2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)


    Lexus Gs430, Gs300. Uzs190 Grs190.A761E Automatic Transmission.Electronic Controlled Automatic Transmission System.
Dtc
  P0985  Shift Solenoid E Control Circuit Low (Shift Solenoid Valve Sr)
  1. Connect the transmission connector to the transmission.

  1. Disconnect the connector from the ECM.

  1. Measure the resistance according to the value(s) in the table below.

    Resistance:
    Tester Connection
    Specified Condition
    20°C (68°F)
    E7 - 2 (SR) - Body ground
    11 to 15 Ω


NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM

3.INSPECT SHIFT SOLENOID VALVE SR


    Lexus Gs430, Gs300. Uzs190 Grs190.A761E Automatic Transmission.Electronic Controlled Automatic Transmission System.
Dtc
  P0985  Shift Solenoid E Control Circuit Low (Shift Solenoid Valve Sr)
  1. Remove the shift solenoid valve SR.

  1. Measure the resistance according to the value(s) in the table below.

    Resistance:
    Tester Connection
    Specified Condition
    20°C (68°F)
    Solenoid Connector (SR) - Solenoid Body (SR)
    11 to 15 Ω
  1. Connect the positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body.

    OK:
    The solenoid makes an operating sound.


NG
REPLACE SHIFT SOLENOID VALVE SR
OK