Meter / Gauge System Fail-Safe Chart

Body Electrical. Lexus Gs430, Gs300. Uzs190 Grs190
Meter. Lexus Gs430, Gs300. Uzs190 Grs190

Meter / Gauge System -- Fail-Safe Chart



WATER TEMPERATURE GAUGE:
Condition
Fail-safe Operation
Fail-safe Deactivation Condition
Water temperature data is interrupted for 5 seconds
Gauge needle indicates below "C"
Water temperature data is received

FUEL SIGNAL (FUEL INJECTION SIGNAL):
Condition
Fail-safe Operation
Fail-safe Deactivation Condition
While engine switch is in on (IG) position, fuel injection signal is interrupted for 60 seconds
Fuel gauge calibration is performed using average fuel consumption data
Engine switch is turned from off to on (IG) and normal data is received

FUEL SIGNAL (GAUGE SIGNAL):
Condition
Fail-safe Operation
Fail-safe Deactivation Condition
While engine switch is in the on (IG) position, sender signal is interrupted for 60 seconds and malfunction signal is received from one of gauges for 10 to 20 seconds
Needle indicates "E", and warning light comes on
Engine switch is turned from off to on (IG) and normal data is received

SHIFT INDICATOR:
Condition
Fail-safe Operation
Fail-safe Deactivation Condition
"P to D" data is interrupted for 3 seconds
All indicators go off
Normal data is received
"S" data is interrupted for 3 seconds
"S" indicator goes off
Normal data is received

GEAR POSITION INDICATOR (1 TO 6):
Condition
Fail-safe Operation
Fail-safe Deactivation Condition
Gear position data is interrupted for 3 seconds or malfunction signal is received
Indicator goes off
Normal data is received

ABS and BRAKE:
Condition
Fail-safe Operation
Fail-safe Deactivation Condition
ABS and brake data is interrupted for 10 seconds
Warning light comes on
Normal data is received

DOOR:
Condition
Fail-safe Operation
Fail-safe Deactivation Condition
Regular data is interrupted
Data received most recently remains displayed
Normal data is received

TAIL:
Condition
Fail-safe Operation
Fail-safe Deactivation Condition
Regular data is interrupted
Data received most recently remains displayed
Normal data is received

BEAM:
Condition
Fail-safe Operation
Fail-safe Deactivation Condition
Regular data is interrupted for 10 seconds or more
Indicator goes off
Normal data is received

TAIL OR HEAD:
Condition
Fail-safe Operation
Fail-safe Deactivation Condition
Regular data is interrupted for 10 seconds or more
Indicator goes off
Normal data is received

FR FOG:
Condition
Fail-safe Operation
Fail-safe Deactivation Condition
Regular data is interrupted for 10 seconds or more
Indicator goes off
Normal data is received

RR FOG:
Condition
Fail-safe Operation
Fail-safe Deactivation Condition
Regular data is interrupted for 10 seconds or more
Indicator goes off
Normal data is received

AIRBAG:
Condition
Fail-safe Operation
Fail-safe Deactivation Condition
Airbag data is interrupted for 10 seconds or there is malfunction in the meter's internal CPU
Warning light comes on
Normal data is received

OUTSIDE TEMP:
Condition
Fail-safe Operation
Fail-safe Deactivation Condition
Abnormal data and sensor malfunctioning data are received
"--°F" is displayed
Normal data is received
Outside temperature data is interrupted for 10 seconds
"E" is displayed
Normal data is received

MULTI-INFORMATION:
Condition
Fail-safe Operation
Fail-safe Deactivation Condition
Cruise information data is interrupted for 60 seconds
Display becomes blank (only measurement units are displayed)
Normal data is received

LIGHT CONTROL RHEOSTAT:
Condition
Fail-safe Operation
Fail-safe Deactivation Condition
Rheostat data is interrupted for 10 seconds or abnormal data is received
Display remains in daytime mode
Normal data is received