Meter / Gauge System Malfunction In Fuel Receiver Gauge
Meter. Lexus Gs430, Gs300. Uzs190 Grs190
WIRING DIAGRAM
INSPECTION PROCEDURE
PERFORM ACTIVE TEST BY INTELLIGENT TESTER
READ VALUE OF INTELLIGENT TESTER
INSPECT FUEL SENDER GAUGE ASSEMBLY (MAIN)
INSPECT FUEL SENDER GAUGE ASSEMBLY (SUB)
CHECK HARNESS AND CONNECTOR (COMBINATION METER - FUEL SENDER GAUGE (MAIN))
CHECK HARNESS AND CONNECTOR (FUEL SENDER GAUGE (SUB) - FUEL SENDER GAUGE (MAIN))
CHECK HARNESS AND CONNECTOR (COMBINATION METER - FUEL SENDER GAUGE (SUB))
METER / GAUGE SYSTEM - Malfunction in Fuel Receiver Gauge |
WIRING DIAGRAM
INSPECTION PROCEDURE
1.PERFORM ACTIVE TEST BY INTELLIGENT TESTER |
Operate the intelligent tester according to the display and select the "Active Test".
- Combination meter:
Item
| Test Details
| Diagnostic Note
|
Fuel Meter Operation
| EMPTY, 1/2, FULL
| -
|
- OK:
- Needle indication is normal.
| REPLACE COMBINATION METER |
|
|
2.READ VALUE OF INTELLIGENT TESTER |
Operate the intelligent tester according to the display and select the "Data List".
- Combination meter:
Item
| Measurement Item/Range (Display)
| Normal Condition
| Diagnostic Note
|
Fuel Input
| Fuel input signal/ Min.: 0, Max.: 255
| Fuel gauge indicates (F): 47 Fuel gauge indicates (3/4): 92 Fuel gauge indicates (1/2): 148 Fuel gauge indicates (1/4): 187 Fuel gauge indicates (E): 205
| -
|
- OK:
- Fuel value signal displayed on the tester is almost the same as needle indication.
| REPLACE COMBINATION METER |
|
|
3.INSPECT FUEL SENDER GAUGE ASSEMBLY (MAIN) |
Measure the voltage of the wire harness side connector.
- Standard voltage:
Tester Connection
| Condition
| Specified Condition
|
V9-2 - V9-3
| Engine switch on (ACC) or on (IG)
| 10 to 14 V
|
Remove the fuel sender gauge assembly.
Connect the fuel sender gauge connector.
Check that the float position is between E and F.
Measure the resistance between the terminals 2 and 1 of connector of the connector.
- Standard resistance:
Float level
| Float Position
| Specified Condition
|
F
| 51.4 to 57.4 mm (2.02 to 2.26 in.)
| 6.5 to 8.5 Ω
|
E
| 121.7 to 127.7 mm (4.79 to 5.03 in.)
| 237.6 to 242.6 Ω
|
| REPLACE FUEL SENDER GAUGE ASSEMBLY |
|
|
4.INSPECT FUEL SENDER GAUGE ASSEMBLY (SUB) |
Measure the voltage of the wire harness side connector.
- Standard voltage:
Tester Connection
| Condition
| Specified Condition
|
W11-2 - W11-3
| Engine switch on (ACC) or on (IG)
| 10 to 14 V
|
Remove the fuel sender gauge assembly.
Connect the fuel sender gauge connector.
Check that the float position is between E and F.
Measure the resistance between terminals 2 and 1 of connector of the connector.
- Standard resistance:
Float level
| Float Position
| Specified Condition
|
F
| 69.9 to 75.9 mm (2.75 to 2.99 in.)
| 6.5 to 8.5 Ω
|
E
| 103.1 to 109.1 mm (4.06 to 4.30 in.)
| 167.9 to 171.9 Ω
|
| REPLACE FUEL SENDER GAUGE ASSEMBLY |
|
|
5.CHECK HARNESS AND CONNECTOR (COMBINATION METER - FUEL SENDER GAUGE (MAIN)) |
Disconnect the V9 fuel sender gauge connector.
Disconnect the L31 meter connector.
Measure the resistance of the wire harness side connector.
- Standard resistance:
Tester Connection
| Condition
| Specified Condition
|
L31-19 - V9-2
| Always
| Below 1 Ω
|
V9-2 - Body ground
| Always
| 10 kΩ or higher
|
| REPAIR OR REPLACE HARNESS AND CONNECTOR |
|
|
6.CHECK HARNESS AND CONNECTOR (FUEL SENDER GAUGE (SUB) - FUEL SENDER GAUGE (MAIN)) |
Disconnect the V9 fuel sender gauge connector.
Disconnect the W11 fuel sender gauge connector.
Measure the resistance of the wire harness side connectors.
- Standard resistance:
Tester Connection
| Condition
| Specified Condition
|
V9-3 - W11-3
| Always
| Below 1 Ω
|
W11-3 - Body ground
| Always
| 10 kΩ or higher
|
| REPAIR OR REPLACE HARNESS AND CONNECTOR |
|
|
7.CHECK HARNESS AND CONNECTOR (COMBINATION METER - FUEL SENDER GAUGE (SUB)) |
Disconnect the W11 fuel sender gauge connector.
Disconnect the L31 meter connector.
Measure the resistance of the wire harness side connectors.
- Standard resistance:
Tester Connection
| Condition
| Specified Condition
|
W11-2 - L31-34
| Always
| Below 1 Ω
|
L31-34 - Body ground
| Always
| 10 kΩ or higher
|
| REPAIR OR REPLACE HARNESS AND CONNECTOR |
|
|