Egr Bypass Valve Switching Valve -- Inspection |
1. INSPECT NO. 1 VACUUM SWITCHING VALVE ASSEMBLY |
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection Condition Specified Condition 1 - 2 20°C (68°F) 33 to 39 Ω 1 - Body ground
2 - Body ground20°C (68°F) 1 MΩ or higher
If the result is not as specified, replace the No. 1 vacuum switching valve assembly.Text in Illustration *a Component without harness connected
(No. 1 vacuum switching valve assembly)
![]() |
Check operation of the No. 1 vacuum switching valve assembly.
When a vacuum of 60 kPa (450 mmHg, 18 in.Hg) is applied to port F, check that air flows from port E to the filter.
Text in Illustration *a Vacuum *b Air *c Port E *d Port F *e Filter Apply battery voltage 12V across terminals 1 and 2.
Text in Illustration *a Air *b Port F *c Port E Check that air flows from port E to port F. If the result is not as specified, replace the No. 1 vacuum switching valve assembly.