Relay (W/ Urea Scr System) -- On-Vehicle Inspection |
1. INSPECT NO. 1 INTEGRATION RELAY |

*a | Component without harness connected (No. 1 Integration Relay) | - | - |
- NOTICE:
- The EDU relay, IG2 relay, EFI MAIN1 relay and EFI MAIN2 relay are built into the No. 1 integration relay.
- Before performing the relay inspections for the relays of the No. 1 integration relay, inspect the EDU, IG2, EFI-MAIN NO. 1 and EFI-MAIN NO. 2 fuses.
Inspect the EDU relay.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection Condition Specified Condition 1C-1 - 1J-5 Battery voltage not applied to terminals 1J-10 and 1J-3 10 kΩ or higher Battery voltage applied to terminals 1J-10 and 1J-3 Below 1 Ω
Inspect the IG2 relay.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection Condition Specified Condition 1C-1 - 1J-7 Battery voltage not applied to terminals 1J-6 and 1J-3 10 kΩ or higher Battery voltage applied to terminals 1J-6 and 1J-3 Below 1 Ω
Inspect the EFI MAIN1 relay.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection Condition Specified Condition 1C-1 - 1J-10 Battery voltage not applied to terminals 1K-7 and 1J-3 10 kΩ or higher Battery voltage applied to terminals 1K-7 and 1J-3 Below 1 Ω
Inspect the EFI MAIN2 relay.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection Condition Specified Condition 1C-1 - 1J-12 Battery voltage not applied to terminals 1J-10 and 1J-3 10 kΩ or higher Battery voltage applied to terminals 1J-10 and 1J-3 Below 1 Ω
2. INSPECT DCU RELAY (DCU) |
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection Condition Specified Condition 3 - 5 Battery voltage not applied to terminals 1 and 2 10 kΩ or higher Battery voltage applied to terminals 1 and 2 Below 1 Ω
![]() |
3. INSPECT NOx PM RELAY (NOx PM) |
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection Condition Specified Condition 3 - 5 Battery voltage not applied to terminals 1 and 2 10 kΩ or higher Battery voltage applied to terminals 1 and 2 Below 1 Ω
![]() |