Manifold Absolute Pressure Sensor -- Installation |
1. INSTALL MANIFOLD ABSOLUTE PRESSURE SENSOR |
Install the manifold absolute pressure sensor bracket and manifold absolute pressure sensor with the 2 nuts.
- Torque:
- 8.0 N*m{82 kgf*cm, 71 in.*lbf}
Attach the vacuum hose to the manifold absolute pressure sensor bracket.
Connect the vacuum hose and manifold absolute pressure sensor connector.