Manifold Absolute Pressure Sensor Installation


  1. INSTALL MANIFOLD ABSOLUTE PRESSURE SENSOR

Manifold Absolute Pressure Sensor -- Installation



1. INSTALL MANIFOLD ABSOLUTE PRESSURE SENSOR
  1. Install the manifold absolute pressure sensor bracket and manifold absolute pressure sensor with the 2 nuts.

    Torque:
    8.0 N*m{82 kgf*cm, 71 in.*lbf}
  1. Attach the vacuum hose to the manifold absolute pressure sensor bracket.

  1. Connect the vacuum hose and manifold absolute pressure sensor connector.