Room Light Switch Inspection
INSPECT ROOM LIGHT SWITCH ASSEMBLY
Room Light Switch -- Inspection |
1. INSPECT ROOM LIGHT SWITCH ASSEMBLY |
Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
Tester Connection
| Switch Condition
| Specified Condition
|
3 (UP) - 4 (E)
| Light control switch off
| 10 kΩ or higher
|
Light control switch UP
| Below 1 Ω
|
2 (DOWN) - 4 (E)
| Light control switch off
| 10 kΩ or higher
|
Light control switch DOWN
| Below 1 Ω
|
Apply battery voltage to the connector and check the LED illumination.
- OK:
Measurement Condition
| Specified Condition
|
Battery positive (+) → Terminal 5 (ILL+) Battery negative (-) → Terminal 1 (E)
| LED illuminates
|
If the result is not as specified, replace the room light switch assembly.
Text in Illustration*a
| Component without harness connected (Room Light Switch)
|