Trip Switch Inspection


  1. INSPECT TRIP SWITCH (w/o TAIL Cancel Switch)

  2. INSPECT TRIP SWITCH (w/ TAIL Cancel Switch)

Trip Switch -- Inspection



1. INSPECT TRIP SWITCH (w/o TAIL Cancel Switch)


  1. Inspect the light control rheostat.



    1. Measure the resistance according to the value(s) in the table below.


      Land Cruiser, Land Cruiser Prado. Grj150 Trj150,155 Kdj150,155 Lj150, Gdj150,155.Meter Gauge Display.Meter / Gauge System.Trip Switch  Inspection


      Standard Resistance:
      for LHD
      Tester Connection
      Switch Condition
      Specified Condition
      5 (T) - 1 (E)
      Always
      8 to 12 kΩ
      7 (RV) - 1 (E)
      Light control rheostat fully turned right → Light control rheostat fully turned left
      Below 100 Ω → 8 to 12 kΩ
      for RHD
      Tester Connection
      Switch Condition
      Specified Condition
      8 (T) - 4 (E)
      Always
      8 to 12 kΩ
      6 (RV) - 4 (E)
      Light control rheostat fully turned right → Light control rheostat fully turned left
      Below 100 Ω → 8 to 12 kΩ
  1. Inspect the ODO/TRIP switch.

    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      for LHD
      Tester Connection
      Switch Condition
      Specified Condition
      4 (A/B) - 1 (E)
      ODO/TRIP switch on (Pushed)
      Below 1 Ω
      ODO/TRIP switch off (Not pushed)
      1 MΩ or higher
      for RHD
      Tester Connection
      Switch Condition
      Specified Condition
      1 (A/B) - 4 (E)
      ODO/TRIP switch on (Pushed)
      Below 1 Ω
      ODO/TRIP switch off (Not pushed)
      1 MΩ or higher
      If the result is not as specified, replace the rheostat.


2. INSPECT TRIP SWITCH (w/ TAIL Cancel Switch)


  1. Inspect the light control rheostat.



    1. Measure the resistance according to the value(s) in the table below.


      Land Cruiser, Land Cruiser Prado. Grj150 Trj150,155 Kdj150,155 Lj150, Gdj150,155.Meter Gauge Display.Meter / Gauge System.Trip Switch  Inspection


      Standard Resistance:
      for LHD
      Tester Connection
      Switch Condition
      Specified Condition
      5 (T) - 6 (TC)
      TAIL cancel switch off → on
      1 MΩ or higher → Below 100 Ω
      5 (T) - 1 (E)
      Always
      8 to 12 kΩ
      7 (RV) - 1 (E)
      Light control rheostat fully turned right → Light control rheostat fully turned left
      Below 100 Ω → 8 to 12 kΩ
      for RHD
      Tester Connection
      Switch Condition
      Specified Condition
      7 (TC) - 8 (T)
      TAIL cancel switch off → on
      1 MΩ or higher → Below 1 Ω
      8 (T) - 4 (E)
      Always
      8 to 12 kΩ
      6 (RV) - 4 (E)
      Light control rheostat fully turned right → Light control rheostat fully turned left
      Below 100 Ω → 8 to 12 kΩ
  1. Inspect the ODO/TRIP switch.

    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      for LHD
      Tester Connection
      Switch Condition
      Specified Condition
      4 (A/B) - 1 (E)
      ODO/TRIP switch on (Pushed)
      Below 1 Ω
      ODO/TRIP switch off (Not pushed)
      1 MΩ or higher
      for RHD
      Tester Connection
      Switch Condition
      Specified Condition
      1 (A/B) - 4 (E)
      ODO/TRIP switch on (Pushed)
      Below 1 Ω
      ODO/TRIP switch off (Not pushed)
      1 MΩ or higher
      If the result is not as specified, replace the rheostat.