Shift Lever -- Inspection |
1. INSPECT TRANSMISSION CONTROL SWITCH |
![]() |
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection Condition Specified Condition 3 (IG) - 7 (S) Shift lever in S, "+" or "-" Below 1 Ω 3 (IG) - 7 (S) Shift lever not in S, "+" or "-" 10 kΩ or higher
If the result is not as specified, replace the transmission floor shift assembly.Text in Illustration *a Component without harness connected
(Transmission Control Switch)