Absorber Control Actuator Inspection
INSPECT ABSORBER CONTROL ACTUATOR
Absorber Control Actuator -- Inspection |
1. INSPECT ABSORBER CONTROL ACTUATOR |
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
for LHTester Connection
| Condition
| Specified Condition
|
1 (FAL+) - 2 (FAL-)
| Always
| 6.4 to 7.2 Ω
|
3 (FBL+) - 4 (FBL-)
| 6.4 to 7.2 Ω
|
Text in Illustration*a
| Component without harness connected (Absorber Control Actuator LH)
|
If the result is not as specified, replace the absorber control actuator.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
for RHTester Connection
| Condition
| Specified Condition
|
1 (FAR+) - 2 (FAR-)
| Always
| 6.4 to 7.2 Ω
|
3 (FBR+) - 4 (FBR-)
| 6.4 to 7.2 Ω
|
Text in Illustration*a
| Component without harness connected (Absorber Control Actuator RH)
|
If the result is not as specified, replace the absorber control actuator.