Purge Valve -- Inspection |
1. INSPECT PURGE VSV |
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection Condition Specified Condition 1 - 2 20°C (68°F) 23 to 26 Ω 1 - Body ground Always 10 MΩ or higher 2 - Body ground Always 10 MΩ or higher
- HINT:
- When measuring the coil resistance make sure that the surface temperature of the purge VSV is 20°C.
![]() |
Check the operation of the purge VSV.
Check that air does not flow from port E to port F.
Text in Illustration *1 Port E *2 Port F *a Does not flow Air pressure Apply battery voltage to the connector and check the VSV operation.
- OK:
Measurement Condition Specified Condition Battery positive (+) → terminal 1
Battery negative (-) → terminal 2Air flows from port E to port F
If the result is not as specified, replace the purge VSV.Text in Illustration *1 Port E *2 Port F Air pressure