Dtc 010 Over Voltage Shutoff
DESCRIPTION
WIRING DIAGRAM
INSPECTION PROCEDURE
CHECK HARNESS AND CONNECTOR (HEATER ASSEMBLY - BATTERY AND BODY GROUND)
DTC 010 Over Voltage Shutoff |
DTC 011 Under Voltage Shutoff |
DESCRIPTION
DTC Code
| DTC Detection Condition
| Trouble Area
|
010
| Battery voltage is 14 V or more for 20 seconds or more.
| - Harness or connector
- Battery
- Heater assembly
|
011
| Battery voltage is 10 V or less for 20 seconds or more.
| - Harness or connector
- Battery
- Heater assembly
|
WIRING DIAGRAM
INSPECTION PROCEDURE
- NOTICE:
- Inspect the fuses for circuits related to this system before performing the following inspection procedure.
1.CHECK HARNESS AND CONNECTOR (HEATER ASSEMBLY - BATTERY AND BODY GROUND) |
Disconnect the heater assembly connector.
Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
Tester Connection
| Condition
| Specified Condition
|
A97-5 (B) - Body ground
| Always
| 11 to 14 V
|
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
A97-1 (E) - Body ground
| Always
| Below 1 Ω
|
Text in Illustration*a
| Front view of wire harness connector (to Heater Assembly)
|
| REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
|