Air Switching Valve -- Inspection |
1. INSPECT AIR SWITCHING VALVE ASSEMBLY |
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection Condition Specified Condition 1 - 2 20°C (68°F) 4.5 to 5.5 Ω 1 - Body ground Always 1 MΩ or higher 2 - Body ground
- HINT:
- When measuring the resistance make sure that the surface temperature of the air switching valve is 20°C.
Check the operation of the air switching valve.
Check that air does not flow from port A to port B.
Text in Illustration *a Port A *b Port B Air - NOTICE:
- Make sure the applied pressure is 30 kPa (0.3 kgf/cm2, 4.4 psi) or less.
Apply battery voltage across terminals 1 and 2.
Text in Illustration *a Component without harness connected
(Air Switching Valve Assembly)*a Port A *c Port B Air - NOTICE:
- Apply voltage for 2 minutes or less.
Check that air flows from port A to port B.
If the result is not as specified, replace the air switching valve assembly.