Vacuum Pump (For 1Kd-Ftv) Inspection
CHECK OPERATION OF CHECK VALVE SUB-ASSEMBLY
CHECK VACUUM PUMP HOUSING
Vacuum Pump (For 1Kd-Ftv) -- Inspection |
1. CHECK OPERATION OF CHECK VALVE SUB-ASSEMBLY |
Check that air flows from the hose side to the pump side.
Text in Illustration*a
| Hose Side
|
*b
| Vacuum Pump Side
|

| Air
|
Check that air does not flow from the pump side to the hose side.
If necessary, replace the check valve sub-assembly.
2. CHECK VACUUM PUMP HOUSING |
Check the inside surface of the housing for scoring.