Drivetrain. Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25
R150Fr151F R156F Manual Transmission Transaxle. Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25
Counter Gear -- Inspection |
1. INSPECT COUNTER GEAR |
Using a micrometer, measure the outside diameter of the counter gear as shown in the illustration.
- Standard outside diameter:
- 29.984 to 30.000 mm (1.1805 to 1.1811 in.)
- Minimum outside diameter:
- 29.984 mm (1.1805 in.)
![]() |