Relay On-Vehicle Inspection
INSPECT STARTER RELAY (ST)
INSPECT GLOW RELAY
Relay -- On-Vehicle Inspection |
1. INSPECT STARTER RELAY (ST) |
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
3 - 5
| Battery voltage not applied to terminals 1 and 2
| 10 kΩ or higher
|
Battery voltage applied to terminals 1 and 2
| Below 1 Ω
|
If the result is not as specified, replace the starter relay.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
3 - 5
| Battery voltage not applied to terminals 1 and 2
| 10 kΩ or higher
|
Battery voltage applied to terminals 1 and 2
| Below 1 Ω
|
If the result is not as specified, replace the glow relay.