Engine Hybrid System. Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25
2Tr-Fbe Fuel. Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25
Solenoid Valve (For Fuel Cut Control) -- Installation |
1. INSTALL SOLENOID VALVE ASSEMBLY |
Install the solenoid valve with the 2 screws.
- Torque:
- 2.5 N*m{25 kgf*cm, 22 in.*lbf}
Install the solenoid valve assembly with the bolt.
- Torque:
- 7.0 N*m{71 kgf*cm, 62 in.*lbf}
Connect the connector and No. 3 fuel hose, No. 2 fuel tube sub-assembly.
2. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL |
- NOTICE:
- When disconnecting the cable, some systems need to be initialized after the cable is reconnected (HILUX_TGN26 RM000004QR3003X.html).
3. INSPECT FOR FUEL LEAK (for Fuel Sub Tank) |
Start the engine.
- NOTICE:
- Perform the inspection while the engine is cold.
- The fuel pump operates only for a calculated time when the coolant temperature is 20°C (68°F) or less and learned ethanol concentration is 85% or more.
Check for fuel leaks.
Check that there are no fuel leaks from the fuel system after doing any maintenance or repairs. If there is a fuel leak, repair or replace parts as necessary.