Engine Hybrid System. Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25
2Tr-Fe Engine Control. Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25
DTC P060A Internal Control Module Monitoring Processor Performance |
DESCRIPTION
The main CPU and sub CPU of the ECM perform data communication between each other. The main CPU monitors the communications and WDC pulses from the sub CPU. When the signal malfunctions below are detected, a DTC is stored.DTC No. | DTC Detection Condition | Trouble Area |
P060A | A CPU reset is performed after one of the following conditions is met (1 trip detection logic):
| ECM |
MONITOR STRATEGY
Required sensors/Components | ECM |
Frequency of operation | Once per driving cycle |
CONFIRMATION DRIVING PATTERN
- Turn the ignition switch off.
- Disconnect the cable from the negative (-) battery terminal and wait for 1 minute.
- Connect the cable to the negative (-) battery terminal.
- Turn the ignition switch to ON and wait for 16 seconds or more.
INSPECTION PROCEDURE
1.CHECK FOR DTC |
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the intelligent tester on.
Clear the DTCs (HILUX_TGN26 RM000000PDK0SXX.html).
Turn the intelligent tester off.
Turn the ignition switch off.
Disconnect the intelligent tester.
Disconnect the cable from the negative (-) battery terminal and wait for 1 minute.
Connect the cable to the negative (-) battery terminal.
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON and turn the intelligent tester on.
Wait 16 seconds or more.
Enter the following menus: Powertrain / Engine and ECT / DTC.
Check for DTCs.
- OK:
- P060A is not output.
|
| ||||
OK | ||
|