Power Window Control System (W/ Jam Protection Function) Auto Up Operation Does Not Fully Close Power Window (Jam Protection Function Is Activated)

Vehicle Exterior. Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25
Window Glass. Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25

DESCRIPTION

INSPECTION PROCEDURE

RESET FRONT POWER WINDOW REGULATOR MOTOR ASSEMBLY LH

CHECK WINDOW GLASS SLIDING MOVEMENT (APPLICABLE LOCATION)

POWER WINDOW CONTROL SYSTEM (w/ Jam Protection Function) - Auto Up Operation does not Fully Close Power Window (Jam Protection Function is Activated)


DESCRIPTION

If the door glass or the front power window regulator motor assembly LH does not operate smoothly, the jam protection function may be triggered automatically, resulting in the auto up function being unable to fully close the window.
HINT:
The jam protection function is only available on the driver side power window.

INSPECTION PROCEDURE

1.RESET FRONT POWER WINDOW REGULATOR MOTOR ASSEMBLY LH
  1. Reset the front power window regulator motor assembly LH (HILUX_TGN26 RM000001DJB01FX.html).

  1. Check that the power window auto up/down function operates normally.

    OK:
    Auto up/down function operates normally.


NG
Go to step 2
OK

END (PROBLEM DUE TO RESET FAILURE)

2.CHECK WINDOW GLASS SLIDING MOVEMENT (APPLICABLE LOCATION)
  1. Remove the installation bolt of the door glass and hold the glass by hand. When raising the glass by hand, check that the glass moves smoothly.

    NOTICE:
    1. Make sure that the glass run is not deformed, and that there is no foreign matter on the glass run.
    2. Make sure that the glass run does not have foreign matter attached to it.
    OK:
    Window glass slides smoothly.


NG
INSTALL DOOR GLASS AND/OR GLASS RUN PROPERLY (APPLICABLE LOCATION)
OK

REPLACE POWER WINDOW REGULATOR MOTOR ASSEMBLY LH (HILUX_TGN26 RM000002STX02NX.html)