Generator (For Denso Made) Installation

Power Source Network. Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25
2Kd-Ftv Battery Charging. Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25

  1. INSTALL GENERATOR ASSEMBLY

  2. INSTALL NO. 2 IDLER PULLEY ASSEMBLY

  3. INSTALL FAN AND GENERATOR V BELT

  4. INSTALL AIR CLEANER ASSEMBLY

  5. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

Generator (For Denso Made) -- Installation



1. INSTALL GENERATOR ASSEMBLY


Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25.2Kd-Ftv Battery Charging.Charging System.Generator (For Denso Made)  Installation
  1. Install the generator with the 2 bolts.

    Torque:
    for bolt A:
    62 N*m{632 kgf*cm, 46 ft.*lbf}
    for bolt B:
    25 N*m{255 kgf*cm, 18 ft.*lbf}
  1. Install the generator wire with the nut.

    Torque:
    9.8 N*m{100 kgf*cm, 87 in.*lbf}
  1. Connect the generator connector.



2. INSTALL NO. 2 IDLER PULLEY ASSEMBLY
  1. Install the spacer, No. 2 idle pulley and pulley plate with the bolt.

    Torque:
    45 N*m{459 kgf*cm, 33 ft.*lbf}


3. INSTALL FAN AND GENERATOR V BELT
  1. Rotate the V-ribbed belt tensioner pulley clockwise, and then install the fan and generator V belt.

    NOTICE:
    Make sure that the fan and generator V belt is set properly on each pulley.
  1. Check that the indicator mark of the V-ribbed belt tensioner (HILUX_TGN26 RM000001475015X.html).



4. INSTALL AIR CLEANER ASSEMBLY
  1. Connect the air cleaner hose.

  1. Install the cleaner with the 2 bolts.

    Torque:
    14 N*m{143 kgf*cm, 10 ft.*lbf}
  1. Tighten the hose clamp.

  1. Connect the connector to the mass air flow meter connector.



5. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
NOTICE:
When disconnecting the cable, some systems need to be initialized after the cable is reconnected (HILUX_TGN26 RM000004QR1003X.html).