Front Passenger Airbag Assembly Removal
PRECAUTION
DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
REMOVE GLOVE COMPARTMENT DOOR ASSEMBLY
REMOVE INSTRUMENT PANEL PASSENGER AIRBAG ASSEMBLY
Front Passenger Airbag Assembly -- Removal |
- NOTICE:
- After turning the ignition switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work (HILUX_TGN26 RM000004QR1006X.html).
2. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL |
- CAUTION:
- Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to disable the SRS system.
- NOTICE:
- When disconnecting the cable, some systems need to be initialized after the cable is reconnected (HILUX_TGN26 RM000004QR3009X.html).
3. REMOVE GLOVE COMPARTMENT DOOR ASSEMBLY |
Slightly bend the upper part of the glove compartment door to release the 2 stoppers and open the glove compartment door until it is horizontal.
Text in Illustration*1
| Stopper
|
Pull the glove compartment door toward the rear of the vehicle to detach the 2 hinges and remove the glove compartment door.
Text in Illustration*1
| Hinge
|
4. REMOVE INSTRUMENT PANEL PASSENGER AIRBAG ASSEMBLY |
Disconnect the connector.
- NOTICE:
- When handling the airbag connector, do not damage the airbag wire harness.
Remove the 2 bolts.
Detach the clamp from the bracket.
Detach the 12 claws and remove the instrument panel passenger airbag assembly.