Dtc P0985 Shift Solenoid E Control Circuit Low (Shift Solenoid Valve Sr)

Drivetrain. Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25
A750F Automatic Transmission Transaxle. Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25

DESCRIPTION

MONITOR DESCRIPTION

WIRING DIAGRAM

INSPECTION PROCEDURE

INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SR)

CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)

INSPECT SHIFT SOLENOID VALVE SR

DTC P0985 Shift Solenoid "E" Control Circuit Low (Shift Solenoid Valve SR)

DTC P0986 Shift Solenoid "E" Control Circuit High (Shift Solenoid Valve SR)


DESCRIPTION

Shifting from 1st to 5th is performed in combination with the ON and OFF operation of the shift solenoid valves SL1, SL2, S1, S2 and SR, which is controlled by the ECM. If an open or short circuit occurs in one of the shift solenoid valves, the ECM controls the remaining normal shift solenoid valves to allow the vehicle to be operated smoothly. In case of an open or short circuit, the ECM stops sending current to the circuit. For details, refer to the fail-safe chart (HILUX_TGN26 RM000000O8L0MKX.html).

DTC Code
DTC Detection Condition
Trouble Area
P0985
The ECM detects a short in the solenoid valve SR circuit 2 times when solenoid valve SR is operated (1-trip detection logic).
  1. Short in shift solenoid valve SR circuit
  2. Shift solenoid valve SR
  3. ECM
P0986
The ECM detects an open in the solenoid valve SR circuit 2 times when solenoid valve SR is not operated (1-trip detection logic).
  1. Open in shift solenoid valve SR circuit
  2. Shift solenoid valve SR
  3. ECM

MONITOR DESCRIPTION

These DTCs indicate an open or short in the shift solenoid valve SR circuit. When there is an open or short circuit in any shift solenoid valve circuit, the ECM detects the problem, illuminates the MIL and stores the DTC. When the shift solenoid valve SR is on, if its resistance is 8 Ω or less, the ECM determines there is a short in the shift solenoid valve SR circuit.
When the shift solenoid valve SR is off, if its resistance is 100 kΩ or higher, the ECM determines there is an open in the shift solenoid valve SR circuit (HILUX_TGN26 RM000000O8L0MKX.html).

WIRING DIAGRAM


Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25.A750F Automatic Transmission Transaxle.Automatic Transmission System (For 1Gr-Fe).
Dtc
  P0985  Shift Solenoid E Control Circuit Low (Shift Solenoid Valve Sr)


INSPECTION PROCEDURE


HINT:
The shift solenoid valve SR turns ON/OFF normally when the shift lever is in D.

ECM gear shift command
1st
2nd
3rd
4th
5th
Shift solenoid valve SR
OFF
OFF
OFF
OFF
ON
1.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SR)


    Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25.A750F Automatic Transmission Transaxle.Automatic Transmission System (For 1Gr-Fe).
Dtc
  P0985  Shift Solenoid E Control Circuit Low (Shift Solenoid Valve Sr)
  1. Disconnect the transmission wire connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    7 (SR) - Body ground
    20°C (68°F)
    11 to 15 Ω
    Text in Illustration
    *a
    Component without harness connected
    (Transmission Wire)


NG
Go to step 3
OK


2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)


    Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25.A750F Automatic Transmission Transaxle.Automatic Transmission System (For 1Gr-Fe).
Dtc
  P0985  Shift Solenoid E Control Circuit Low (Shift Solenoid Valve Sr)
  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    C130-9 (SR) - Body ground
    20°C (68°F)
    11 to 15 Ω
    Text in Illustration
    *a
    Rear view of wire harness connector
    (to ECM)


NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM (HILUX_TGN26 RM000000VW202SX.html)

3.INSPECT SHIFT SOLENOID VALVE SR


    Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25.A750F Automatic Transmission Transaxle.Automatic Transmission System (For 1Gr-Fe).
Dtc
  P0985  Shift Solenoid E Control Circuit Low (Shift Solenoid Valve Sr)
  1. Remove shift solenoid valve SR.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    Shift solenoid valve SR connector terminal - Shift solenoid valve SR body
    20°C (68°F)
    11 to 15 Ω
  1. Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

    OK:
    Measurement Condition
    Specified Condition
    1. Battery positive (+) → Shift solenoid valve SR connector
    2. Battery negative (-) → Shift solenoid valve SR body
    Valve moves and makes operating noise
Text in Illustration
*a
Component without harness connected
(Shift Solenoid Valve SR)


NG
REPLACE SHIFT SOLENOID VALVE SR (HILUX_TGN26 RM0000013FG02KX_01_0002.html)
OK

REPAIR OR REPLACE TRANSMISSION WIRE (HILUX_TGN26 RM0000013C1047X.html)