Dtc P0985 Shift Solenoid E Control Circuit Low (Shift Solenoid Valve Sr)

Drivetrain. Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25
A750F Automatic Transmission Transaxle. Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25

DESCRIPTION

MONITOR DESCRIPTION

WIRING DIAGRAM

INSPECTION PROCEDURE

INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SR)

CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - TCM)

INSPECT SHIFT SOLENOID VALVE SR

DTC P0985 Shift Solenoid "E" Control Circuit Low (Shift Solenoid Valve SR)

DTC P0986 Shift Solenoid "E" Control Circuit High (Shift Solenoid Valve SR)


DESCRIPTION

Shifting from 1st to 5th is performed in combination with the ON and OFF operation of shift solenoid valves SL1, SL2, S1, S2 and SR, which are controlled by the TCM. If an open or short circuit occurs in one of the shift solenoid valves, the TCM controls the remaining normal shift solenoid valves to allow the vehicle to be operated smoothly. In the case of an open or short circuit, the TCM stops sending current to the circuit. For details, refer to the fail-safe chart (HILUX_TGN26 RM000000O8L0OLX.html).

DTC Code
DTC Detection Condition
Trouble Area
P0985
TCM detects a short in the solenoid valve SR circuit 2 times when solenoid valve SR is operated (1-trip detection logic).
  1. Short in shift solenoid valve SR circuit
  2. Shift solenoid valve SR
  3. TCM
P0986
TCM detects an open in the solenoid valve SR circuit 2 times when solenoid valve SR is not operated (1-trip detection logic).
  1. Open in shift solenoid valve SR circuit
  2. Shift solenoid valve SR
  3. TCM

MONITOR DESCRIPTION

These DTCs indicate an open or short in the shift solenoid valve SR circuit. When there is an open or short circuit in any shift solenoid valve circuit, the TCM detects the problem, illuminates the MIL and stores the DTC. When shift solenoid valve SR is on, if its resistance is 8 Ω or less, the TCM determines there is a short in the shift solenoid valve SR circuit.
When shift solenoid valve SR is off, if its resistance is 100 kΩ or higher, the TCM determines there is an open in the shift solenoid valve SR circuit (HILUX_TGN26 RM000000O8L0OLX.html).

WIRING DIAGRAM


Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25.A750F Automatic Transmission Transaxle.Automatic Transmission System (For 1Gr-Fe).
Dtc
  P0985  Shift Solenoid E Control Circuit Low (Shift Solenoid Valve Sr)


INSPECTION PROCEDURE


HINT:
Shift solenoid valve SR is turned ON/OFF normally when the shift lever is in D.

TCM gear shift command
1st
2nd
3rd
4th
5th
Shift solenoid valve SR
OFF
OFF
OFF
OFF
ON
1.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SR)


    Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25.A750F Automatic Transmission Transaxle.Automatic Transmission System (For 1Gr-Fe).
Dtc
  P0985  Shift Solenoid E Control Circuit Low (Shift Solenoid Valve Sr)
  1. Disconnect the transmission wire connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    7 (SR) - Body ground
    20°C (68°F)
    11 to 15 Ω
    Text in Illustration
    *a
    Component without harness connected
    (Transmission Wire)


NG
Go to step 3
OK


2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - TCM)


    Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25.A750F Automatic Transmission Transaxle.Automatic Transmission System (For 1Gr-Fe).
Dtc
  P0985  Shift Solenoid E Control Circuit Low (Shift Solenoid Valve Sr)
  1. Disconnect the TCM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    C24-16 (SR) - Body ground
    20°C (68°F)
    11 to 15 Ω
    Text in Illustration
    *a
    Rear view of wire harness connector
    (to TCM)


NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE TCM (HILUX_TGN26 RM0000048F3005X.html)

3.INSPECT SHIFT SOLENOID VALVE SR


    Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25.A750F Automatic Transmission Transaxle.Automatic Transmission System (For 1Gr-Fe).
Dtc
  P0985  Shift Solenoid E Control Circuit Low (Shift Solenoid Valve Sr)
  1. Remove shift solenoid valve SR.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    Shift solenoid valve SR connector terminal - Shift solenoid valve SR body
    20°C (68°F)
    11 to 15 Ω
  1. Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

    OK:
    Measurement Condition
    Specified Condition
    1. Battery positive (+) → Shift solenoid valve SR connector
    2. Battery negative (-) → Shift solenoid valve SR body
    Valve moves and makes an operating noise
Text in Illustration
*a
Component without harness connected
(Shift Solenoid Valve SR)


NG
REPLACE SHIFT SOLENOID VALVE SR (HILUX_TGN26 RM0000013FG02KX_01_0002.html)
OK

REPAIR OR REPLACE TRANSMISSION WIRE (HILUX_TGN26 RM0000013C1047X.html)