Yaw Rate And Acceleration Sensor (W/ Vsc) Installation

Brake. Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25
Brake Control Dynamic Control Systems. Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25

  1. INSTALL YAW RATE SENSOR ASSEMBLY

  2. INSTALL SENSOR BRACKET

  3. INSTALL FLOOR CARPET COVER

  4. INSTALL FRONT SEAT ASSEMBLY RH

  5. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

  6. PERFORM YAW RATE SENSOR ZERO POINT CALIBRATION

Yaw Rate And Acceleration Sensor (W/ Vsc) -- Installation



1. INSTALL YAW RATE SENSOR ASSEMBLY
  1. Connect the connector.

    NOTICE:
    Securely connect the connector.
  1. Install the yaw rate sensor to the crossmember.

    NOTICE:
    1. Do not use any parts which have been dropped or struck.
    2. Make sure that there is no foreign matter or carpet between the bracket of the sensor and crossmember.
    3. Do not do anything to deform the bracket of the sensor, such as kicking or stepping on it.


2. INSTALL SENSOR BRACKET
  1. Install the sensor bracket with the 2 bolts.

    Torque:
    14 N*m{138 kgf*cm, 10 ft.*lbf}


3. INSTALL FLOOR CARPET COVER
  1. Insert the floor carpet cover into the sensor bracket.

  1. Insert the positioning boss of the floor carpet cover into the hole in the bracket of the sensor.

  1. Attach the 4 claws to install the floor carpet cover.



4. INSTALL FRONT SEAT ASSEMBLY RH
  1. for Power Seat:
    (HILUX_TGN26 RM000003NZV013X.html)

  1. for Separate Seat Type:
    (HILUX_TGN26 RM000000Z8T0APX.html)



5. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
NOTICE:
When disconnecting the cable, some systems need to be initialized after the cable is reconnected (HILUX_TGN26 RM000004QR300CX.html).


6. PERFORM YAW RATE SENSOR ZERO POINT CALIBRATION
(HILUX_TGN26 RM000000XHR073X.html)