Charging System Charging Failure
INSPECTION PROCEDURE
CHECK LOCK FUNCTION OF GENERATOR CLUTCH PULLEY
CHECK GENERATOR PULLEY WITH CLUTCH (UNIT INSPECTION)
CHARGING SYSTEM - Charging Failure |
INSPECTION PROCEDURE
1.CHECK LOCK FUNCTION OF GENERATOR CLUTCH PULLEY |
Start the engine and visually check that the generator rotor assembly (fan) in the generator assembly is operating.
- OK:
- The generator rotor assembly (fan) is operating.
2.CHECK GENERATOR PULLEY WITH CLUTCH (UNIT INSPECTION) |
Remove the generator assembly (COROLLA_ZRE142 RM00000219700JX.html).
Check the installation condition of the generator pulley cap.
- OK:
- The generator pulley cap is not loose or missing.
Check for forming of particles due to friction (for dry type pulley) or grease leaks (for wet type pulley).
- OK:
- There are no large amount of particles (for dry type pulley) or grease leaks (for wet type pulley).
Check the generator pulley with clutch for misalignment (interference with the generator assembly).
- OK:
- The generator pulley with clutch is not misaligned (no interference with the generator assembly).
Turn the generator pulley with clutch clockwise and counterclockwise by hand and check for noise.
- OK:
- Noise does not occur when turned in both directions.
Turn the generator pulley with clutch clockwise and counterclockwise by hand and visually check for runout.
- OK:
- The generator pulley with clutch does not have runout.
Hold the generator rotor assembly (fan) in the generator assembly with a screwdriver, and check that the generator pulley with clutch locks when turned clockwise and turns freely when turned counterclockwise.
- OK:
- The generator pulley with clutch locks when turned clockwise and turns freely when turned counterclockwise.