Window Defogger System (For Automatic Air Conditioning System) How To Proceed With Troubleshooting
VEHICLE BROUGHT TO WORKSHOP
CUSTOMER PROBLEM ANALYSIS
INSPECT BATTERY VOLTAGE
PROBLEM SYMPTOMS TABLE
OVERALL ANALYSIS AND TROUBLESHOOTING
REPAIR OR REPLACE
CONFIRMATION TEST
Window Defogger System (For Automatic Air Conditioning System) -- How To Proceed With Troubleshooting |
- HINT:
- Use the following procedure to troubleshoot the defogger system.
- The Techstream should be used in step 5.
1.VEHICLE BROUGHT TO WORKSHOP |
2.CUSTOMER PROBLEM ANALYSIS |
- HINT:
- In troubleshooting, confirm that the problem symptoms have been accurately identified. Preconceptions should be discarded in order to make an accurate judgment. To clearly understand what the problem symptoms are, it is extremely important to ask the customer about the problem and the conditions at the time the malfunction occurred.
- Gather as much information as possible for reference. Past problems that seem unrelated may also help in some cases.
- The following 5 items are important points in the problem analysis:
What
| Vehicle model, system name
|
When
| Date, time, occurrence frequency
|
Where
| Road conditions
|
Under what conditions?
| Driving conditions, weather conditions
|
How did it happen?
| Problem symptoms
|
3.INSPECT BATTERY VOLTAGE |
Measure the battery voltage.
- Standard Voltage:
- 11 to 14 V
If the voltage is below 11 V, recharge or replace the battery before proceeding to the next step.
- Result:
Result
| Proceed to
|
Fault is not listed in problem symptoms table
| A
|
Fault is listed in problem symptoms table
| B
|
5.OVERALL ANALYSIS AND TROUBLESHOOTING |
Terminals of ECU (COROLLA_ZRE142 RM000000WPS09EX.html)
Data List / Active Test (COROLLA_ZRE142 RM000000WPV05RX.html)
On-vehicle Inspection (COROLLA_ZRE142 RM000000U8V067X.html)