Engine. Camry. Acv40 Gsv40
2Gr-Fe Cooling. Camry. Acv40 Gsv40
Radiator -- On-Vehicle Cleaning |
1. INSPECT FINS BLOCKAGE |
If the fins are clogged, wash them with water or a steam cleaner. Dry with compressed air.
- NOTICE:
- If the distance between the steam cleaner and the core is too close, the fins may become damaged. Keep the following injection distance.
- Standard:
Injection Distance Injection Pressure 300 mm (11.81 in.) 2,942 to 4,903 kPa
(30 to 50 kg/cm2, 427 to 711 psi)500 mm (19.69 in.) 4,903 to 7,845 kPa
(50 to 80 kg/cm2, 711 to 1,138 psi)
- If the fins are bent, straighten them with a screwdriver or pliers.
- Never apply water directly onto the electronic components.
![]() |