Air Conditioning System Actuator Check

Air Conditioning. Camry. Acv40 Gsv40
  1. ACTUATOR CHECK

Air Conditioning System -- Actuator Check



ACTUATOR CHECK
  1. Start the engine and warm it up.

  2. Perform the indicator check (CAMRY_ACV40 RM000000T8Q02KX.html).



  3. Camry. Acv40 Gsv40.Air Conditioning.Air Conditioning System.Air Conditioning System  Actuator Check
  4. Push the "R/F" switch to perform the actuator check.

    HINT:
    Be sure to perform the actuator check after starting the engine.


  5. Camry. Acv40 Gsv40.Air Conditioning.Air Conditioning System.Air Conditioning System  Actuator Check
  6. As the actuator check is repeated from steps 1 to 10 at 1 second intervals, check the temperature and air flow visually and by hand.

    HINT:
    1. The display blinks at 1 second intervals in the step operation.
    2. Push the "OFF" switch to finish panel diagnosis.
    3. Push the "AUTO" switch to enter the sensor check mode.

    Step No.
    Display Code
    Conditions
    Blower Level
    Air Mix Damper
    Airflow Vent
    Air Inlet Damper
    Compressor
    1
    0
    0
    0% open
    FACE
    FRESH
    OFF
    2
    1
    1
    0% open
    FACE
    FRESH
    OFF
    3
    2
    17
    0% open
    FACE
    RECIRCULATION / FRESH
    ON
    4
    3
    17
    0% open
    FACE
    RECIRCULATION
    ON
    5
    4
    17
    50% open
    B/L
    RECIRCULATION
    ON
    6
    5
    17
    50% open
    B/L
    RECIRCULATION
    ON
    7
    6
    17
    50% open
    FOOT
    FRESH
    ON
    8
    7
    17
    100% open
    FOOT-0
    FRESH
    ON
    9
    8
    17
    100% open
    F/D
    FRESH
    ON
    10
    9
    31
    100% open
    DEF
    FRESH
    ON


  7. Camry. Acv40 Gsv40.Air Conditioning.Air Conditioning System.Air Conditioning System  Actuator Check
  8. If the steps are difficult to read because they change automatically, push the "MODE" switch to display the steps one at a time so that they can be read easily. The items are displayed step by step each time the "MODE" switch is pushed.

    HINT:
    1. Push the "OFF" switch to finish panel diagnosis.
    2. Push the "R/F" switch to enter the sensor check mode.