Can Communication System (For Lhd) Combination Meter Ecu Communication Stop Mode
DESCRIPTION
WIRING DIAGRAM
INSPECTION PROCEDURE
CHECK CAN BUS LINE FOR DISCONNECTION (COMBINATION METER MAIN BUS WIRE)
CHECK HARNESS AND CONNECTOR (ES, IG+, B2)
CAN COMMUNICATION SYSTEM (for LHD) - Combination Meter ECU Communication Stop Mode |
DESCRIPTION
Detection Item
| Symptom
| Trouble Area
|
Combination Meter ECU Communication Stop Mode
| - "Combination Meter" not displayed on "Communication Bus Check" screen of intelligent tester
- Applies to "Combination Meter ECU Communication Stop Mode" in "DTC combination table"
| - Power source circuit of the combination meter ECU
- Combination meter main wire or connector
- Combination meter
|
WIRING DIAGRAM
INSPECTION PROCEDURE
- NOTICE:
- Turn the ignition switch off before measuring the resistance of the CAN main wire and CAN branch wires.
- After the ignition switch is turned off, check that the key reminder warning system and lighting system are not operating.
- Before measuring the resistance, leave the vehicle as is for at least 1 minute and do not operate the ignition switch, any other switches or the doors. If doors need to be opened in order to check connectors, open the doors and leave them open.
- HINT:
- Operating the ignition switch, any other switches or any triggers related ECU and sensor communication on the CAN, which would cause resistance reading variations.
1.CHECK CAN BUS LINE FOR DISCONNECTION (COMBINATION METER MAIN BUS WIRE) |
Turn the ignition switch off.
Disconnect the combination meter ECU connector.
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
| Condition
| Specified Condition
|
F1-17 (CANH) - F1-18 (CANL)
| Ignition switch off
| 108 to 132 Ω
|
| REPAIR OR REPLACE CAN BUS MAIN WIRE OR CONNECTOR (COMBINATION METER MAIN BUS LINE) |
|
|
2.CHECK HARNESS AND CONNECTOR (ES, IG+, B2) |
Disconnect the combination meter connector.
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
| Condition
| Specified Condition
|
F1-24 (ES) - Body ground
| Always
| Below 1 Ω
|
Measure the voltage according to the value(s) in the table below.
- Standard voltage:
Tester Connection
| Condition
| Specified Condition
|
F1-13 (IG+) - Body ground
| Ignition switch on
| 10 to 14 V
|
F1-2 (B2) - Body ground
| Always
| 10 to 14 V
|
| REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
|
OK |
|
|
|
REPLACE COMBINATION METER ASSEMBLY |
|