Land Cruiser URJ200 URJ202 GRJ200 VDJ200 - SUPPLEMENTAL RESTRAINT SYSTEMS

SPIRAL CABLE - INSPECTION

1. INSPECT SPIRAL CABLE

If there are any defects as mentioned below, replace the spiral cable with a new one:


Scratches, cracks, dents or chips on the connector or the spiral cable.

Spiral Cable - Inspection. SUPPLEMENTAL RESTRAINT SYSTEMS. Land Cruiser URJ200  URJ202 GRJ200 VDJ200

Check the spiral cable.

Set the spiral cable to the center position ().

Measure the resistance between each terminal of the spiral cable according to the table below.

After setting the spiral cable to the center position, rotate the spiral cable 2.5 times clockwise, and measure the resistance as shown. Then rotate the spiral cable 5 times counterclockwise, and measure the resistance as shown.

  • Standard Resistance:
  • Tester ConnectionConditionSpecified Condition
    E13-1 - B2AlwaysBelow 1 Ω
    E13-2 - B1AlwaysBelow 1 Ω
    E13-3 - A1AlwaysBelow 1 Ω
    E13-4 - A2AlwaysBelow 1 Ω
    E12-6 - z36-10AlwaysBelow 1 Ω
    E12-5 - z36-9AlwaysBelow 1 Ω
    E12-4 - z36-8AlwaysBelow 1 Ω
    E12-3 - z36-7AlwaysBelow 1 Ω
    E12-2 - z36-6AlwaysBelow 1 Ω
    E12-2 - z37-4AlwaysBelow 1 Ω
    E12-1 - z37-3AlwaysBelow 1 Ω
    E12-12 - z36-5AlwaysBelow 1 Ω
    E12-11 - z36-4AlwaysBelow 1 Ω
    E12-10 - z36-3AlwaysBelow 1 Ω
    E12-9 - z36-2AlwaysBelow 1 Ω
    E12-8 - z36-1AlwaysBelow 1 Ω
    E12-8 - z37-2AlwaysBelow 1 Ω
    E12-7 - z37-1AlwaysBelow 1 Ω

After setting the spiral cable to the center position, rotate the spiral cable 2.5 times clockwise. Then while rotating the spiral cable 5 times counterclockwise, measure the resistance as shown.

  • Standard Resistance:
  • Tester ConnectionConditionSpecified Condition
    E13-1 - B2AlwaysBelow 1 Ω
    E13-2 - B1AlwaysBelow 1 Ω
    E13-3 - A1AlwaysBelow 1 Ω
    E13-4 - A2AlwaysBelow 1 Ω
    E12-6 - z36-10AlwaysBelow 1 Ω
    E12-5 - z36-9AlwaysBelow 1 Ω
    E12-4 - z36-8AlwaysBelow 1 Ω
    E12-3 - z36-7AlwaysBelow 1 Ω
    E12-2 - z36-6AlwaysBelow 1 Ω
    E12-2 - z37-4AlwaysBelow 1 Ω
    E12-1 - z37-3AlwaysBelow 1 Ω
    E12-12 - z36-5AlwaysBelow 1 Ω
    E12-11 - z36-4AlwaysBelow 1 Ω
    E12-10 - z36-3AlwaysBelow 1 Ω
    E12-9 - z36-2AlwaysBelow 1 Ω
    E12-8 - z36-1AlwaysBelow 1 Ω
    E12-8 - z37-2AlwaysBelow 1 Ω
    E12-7 - z37-1AlwaysBelow 1 Ω
  • NOTICE:
  • As the spiral cable may break, do not rotate the spiral cable more than the specified amount.