Land Cruiser URJ200 URJ202 GRJ200 VDJ200 - SEAT

SEAT HEATER SYSTEM - ON-VEHICLE INSPECTION

1. INSPECT SEAT HEATER CONTROL SUB-ASSEMBLY (for Front Side)
Seat Heater System - On-Vehicle Inspection. SEAT. Land Cruiser URJ200  URJ202 GRJ200 VDJ200

Disconnect the c13 and c1 heater control connectors.

Measure the resistance according to the value(s) in the table below.

  • Standard Resistance:
  • for LH Side
    Tester ConnectionSpecified Condition
    c13-6 (E) - Body groundBelow 1 Ω
  • for RH Side
    Tester ConnectionSpecified Condition
    c1-6 (E) - Body groundBelow 1 Ω

If the result is not as specified, there may be a malfunction on the wire harness side.


Measure the voltage according to the value(s) in the table below.

  • Standard Voltage:
  • for LH Side
    Tester ConnectionSwitch ConditionSpecified Condition
    c13-1 (SWL) - c13-6 (E)Engine switch on (IG), seat heater switch offBelow 1 V
    Engine switch on (IG), seat heater switch on11 to 14 V
    c13-4 (B) - c13-6 (E)Engine switch offBelow 1 V
    Engine switch on (IG)11 to 14 V
  • for RH Side
    Tester ConnectionSwitch ConditionSpecified Condition
    c1-1 (SWR) - c1-6 (E)Engine switch on (IG), seat heater switch offBelow 1 V
    Engine switch on (IG), seat heater switch on11 to 14 V
    c1-4 (B1) - c1-6 (E)Engine switch offBelow 1 V
    Engine switch on (IG)11 to 14 V

If the result is not as specified, there may be a malfunction on the wire harness side.


Connect the c13 and c1 heater control connectors.

Seat Heater System - On-Vehicle Inspection. SEAT. Land Cruiser URJ200  URJ202 GRJ200 VDJ200

Measure the voltage according to the value(s) in the table below.

  • Standard Voltage:
  • for LH Side
    Tester ConnectionSwitch ConditionSpecified Condition
    c13-5 (THL) - Body groundEngine switch on (IG), seat heater switch on, volume Min→ MaxGradual increase from below 1 V to 11 to 14 V
  • for RH Side
    Tester ConnectionSwitch ConditionSpecified Condition
    c1-5 (THR) - Body groundEngine switch on (IG), seat heater switch on, volume Min → MaxGradual increase from below 1 V to 11 to 14 V

If the result is not as specified, the seat heater control may have a malfunction.