Land Cruiser URJ200 URJ202 GRJ200 VDJ200 - METER / GAUGE / DISPLAY

DESCRIPTION

WIRING DIAGRAM

INSPECTION PROCEDURE

READ VALUE USING INTELLIGENT TESTER (LIGHT CONTROL RHEOSTAT)

INSPECT LIGHT CONTROL RHEOSTAT (TRIP SWITCH)

CHECK HARNESS AND CONNECTOR (COMBINATION METER - LIGHT CONTROL RHEOSTAT AND BODY GROUND)

METER / GAUGE SYSTEM - Odo/Trip Switch Malfunction

DESCRIPTION

w/ Multi-information Display:


The ODO/TRIP display of the meter changes each time the ODO/TRIP switch on the light control rheostat is pressed.


  • HINT:
  • For more information about changing between displays, refer to the owner's manual.

WIRING DIAGRAM

Meter / Gauge System - Odo/Trip Switch Malfunction. METER / GAUGE / DISPLAY. Land Cruiser URJ200  URJ202 GRJ200 VDJ200

INSPECTION PROCEDURE

1.READ VALUE USING INTELLIGENT TESTER (LIGHT CONTROL RHEOSTAT)

Operate the intelligent tester according to the display and select Data List.

Combination Meter
Tester DisplayMeasurement Item/RangeNormal ConditionDiagnostic Note
ODO/TRIP Change SWTrip switch (ODO/TRIP switch) condition/ON or OFFON: Trip switch pushed
OFF: Trip switch not pushed
-
  • OK:
  • Switch condition (ON/OFF) can be switched by actual operation.
NG
Go to step 2
OK
REPLACE COMBINATION METER ASSEMBLY ()
2.INSPECT LIGHT CONTROL RHEOSTAT (TRIP SWITCH)
Meter / Gauge System - Odo/Trip Switch Malfunction. METER / GAUGE / DISPLAY. Land Cruiser URJ200  URJ202 GRJ200 VDJ200

Remove the light control rheostat ().

Measure the resistance according to the value(s) in the table below.

  • Standard Resistance:
  • Tester ConnectionSwitch ConditionSpecified Condition
    4 (A/B) - 1 (E)TRIP switch ON (Pushed)Below 200 Ω
    TRIP switch OFF (Not pushed)1 MΩ or higher
NG
REPLACE LIGHT CONTROL RHEOSTAT ()
OK
3.CHECK HARNESS AND CONNECTOR (COMBINATION METER - LIGHT CONTROL RHEOSTAT AND BODY GROUND)
Meter / Gauge System - Odo/Trip Switch Malfunction. METER / GAUGE / DISPLAY. Land Cruiser URJ200  URJ202 GRJ200 VDJ200

Disconnect the E8 ECU connector.

Disconnect the E9 switch connector.

Measure the resistance according to the value(s) in the table below.

  • Standard Resistance:
  • Tester ConnectionConditionSpecified Condition
    E8-4 (RSET) - E9-4 (A/B)AlwaysBelow 1 Ω
    E8-23 (E2) - E9-1 (E)
    E8-23 (E2) - Body ground
    E8-4 (RSET) or E9-4 (A/B) - Body ground10 kΩ or higher
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK
REPLACE COMBINATION METER ASSEMBLY ()