Land Cruiser URJ200 URJ202 GRJ200 VDJ200 - INTERIOR PANELS / TRIM

FRONT CONSOLE BOX (w/ Cool Box) - INSPECTION

1. INSPECT COOLER CONTROL SWITCH SUB-ASSEMBLY
Front Console Box (W/ Cool Box) - Inspection. INTERIOR PANELS / TRIM. Land Cruiser URJ200  URJ202 GRJ200 VDJ200

Measure the resistance according to the value(s) in the table below.

  • Standard Resistance:
  • Tester ConnectionSwitch ConditionSpecified Condition
    1 - 2OnBelow 1 Ω
    1 - 2Off10 kΩ or higher

Apply battery voltage to the cooler control switch connector and check that the indicator illuminates.

  • OK:
  • Measurement ConditionSpecified Condition
    Battery positive (+) → Terminal 3
    Battery negative (-) → Terminal 4
    indicator illuminates

If the result is not as specified, replace the cooler control switch.


2. INSPECT NO. 1 COOLER BLOWER MOTOR SUB-ASSEMBLY
Front Console Box (W/ Cool Box) - Inspection. INTERIOR PANELS / TRIM. Land Cruiser URJ200  URJ202 GRJ200 VDJ200

Apply battery voltage to the blower motor connector and check the operation of the blower motor.

  • OK:
  • Measurement ConditionSpecified Condition
    Battery positive (+) → Terminal 1
    Battery negative (-) → Terminal 2
    Motor operates smoothly

If the result is not as specified, replace the blower motor.


3. INSPECT NO. 3 COOLER THERMISTOR
Front Console Box (W/ Cool Box) - Inspection. INTERIOR PANELS / TRIM. Land Cruiser URJ200  URJ202 GRJ200 VDJ200

Measure the resistance according to the value(s) in the table below.

  • Standard Resistance:
  • Tester ConnectionConditionSpecified Condition
    1 - 2-10°C (14°F)7.40 to 9.20 kΩ
    1 - 2-5°C (23°F)5.65 to 7.00 kΩ
    1 - 20°C (32°F)4.35 to 5.40 kΩ
    1 - 25°C (41°F)3.40 to 4.20 kΩ
    1 - 210°C (50°F)2.68 to 3.30 kΩ
    1 - 215°C (59°F)2.10 to 2.60 kΩ
    1 - 220°C (68°F)1.66 to 2.10 kΩ
    1 - 225°C (77°F)1.32 to 1.66 kΩ
    1 - 230°C (86°F)1.05 to 1.35 kΩ
  • NOTICE:
Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
When measuring, the sensor temperature must be the same as the ambient temperature.
  • HINT:
As the temperature increases, the resistance decreases (see the graph).