Land Cruiser URJ200 URJ202 GRJ200 VDJ200 - METER / GAUGE / DISPLAY

DESCRIPTION

WIRING DIAGRAM

INSPECTION PROCEDURE

READ VALUE USING INTELLIGENT TESTER (FUEL SENDER GAUGE)

CHECK HARNESS AND CONNECTOR (COMBINATION METER - PUMP AND GAUGE AND BODY GROUND)

INSPECT FUEL SUCTION WITH PUMP AND GAUGE TUBE ASSEMBLY

INSPECT FUEL SENDER GAUGE ASSEMBLY

CHECK COMBINATION METER TYPE

DTC B1500 Fuel Sender Open Detected

DESCRIPTION

This DTC is output when the combination meter detects a fuel sender gauge malfunction via the CAN.

DTC CodeDTC Detection ConditionTrouble Area
B1500When the combination meter detects a fuel sender gauge malfunction.
Harness or connector
Combination meter assembly
Fuel suction with pump and gauge tube assembly
Fuel sender gauge assembly

WIRING DIAGRAM

Dtc B1500  Fuel Sender Open Detected. METER / GAUGE / DISPLAY. Land Cruiser URJ200  URJ202 GRJ200 VDJ200

INSPECTION PROCEDURE

1.READ VALUE USING INTELLIGENT TESTER (FUEL SENDER GAUGE)

Operate the intelligent tester according to the display and select the Data List ().

Combination Meter
Tester DisplayMeasurement Item/RangeNormal ConditionDiagnostic Note
Fuel InputFuel sender gauge (main) input signal/Min.: 0, Max.: 127.5Fuel sender input valueUnit: L
  • OK:
  • Fuel value displayed on the intelligent tester is almost the same as needle indication.
Result
ResultProceed to
NGA
OK (w/ Multi-information Display)B
OK (w/o Multi-information Display)C
B
REPLACE COMBINATION METER ASSEMBLY ()
C
REPLACE COMBINATION METER ASSEMBLY ()
A
2.CHECK HARNESS AND CONNECTOR (COMBINATION METER - PUMP AND GAUGE AND BODY GROUND)

Dtc B1500  Fuel Sender Open Detected. METER / GAUGE / DISPLAY. Land Cruiser URJ200  URJ202 GRJ200 VDJ200

Disconnect the E7 and E8 combination meter assembly connectors.

Disconnect the N1 fuel suction with pump and gauge tube assembly connector.

Measure the resistance according to the value(s) in the table below.

  • Standard Resistance:
  • Tester ConnectionConditionSpecified Condition
    E8-9 (L) - N1-2 (FS)AlwaysBelow 1 Ω
    E8-21 (E) - N1-3 (FE)AlwaysBelow 1 Ω
    E7-15 (ET) - Body groundAlwaysBelow 1 Ω
    E8-9 (L) or N1-2 (FS) - Body groundAlways10 kΩ or higher
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK
3.INSPECT FUEL SUCTION WITH PUMP AND GAUGE TUBE ASSEMBLY
Dtc B1500  Fuel Sender Open Detected. METER / GAUGE / DISPLAY. Land Cruiser URJ200  URJ202 GRJ200 VDJ200

Remove the fuel sender gauge assembly.

  • HINT:
for 1GR-FE ()
for 1UR-FE ()
for 3UR-FE ()
for 1VD-FTV ()

Measure the resistance according to the value(s) in the table below.

  • Standard Resistance:
  • Tester ConnectionConditionSpecified Condition
    A-2 (FS) - B-2 (FS)AlwaysBelow 1 Ω
    A-3 (FE) - B-1 (FE)AlwaysBelow 1 Ω
Text in Illustration
*1Component without harness connected
(Fuel Suction with Pump and Gauge Tube Assembly)
*2Connector A
*3Connector B
Result
ResultProceed to
OKA
NG (for 1GR-FE)B
NG (for 1UR-FE)C
NG (for 3UR-FE)D
NG (for 1VD-FTV)E
B
REPLACE FUEL SUCTION WITH PUMP AND GAUGE TUBE ASSEMBLY ()
C
REPLACE FUEL SUCTION WITH PUMP AND GAUGE TUBE ASSEMBLY ()
D
REPLACE FUEL SUCTION WITH PUMP AND GAUGE TUBE ASSEMBLY ()
E
REPLACE FUEL SUCTION WITH PUMP AND GAUGE TUBE ASSEMBLY ()
A
4.INSPECT FUEL SENDER GAUGE ASSEMBLY
Dtc B1500  Fuel Sender Open Detected. METER / GAUGE / DISPLAY. Land Cruiser URJ200  URJ202 GRJ200 VDJ200

Remove the fuel sender gauge assembly.

  • HINT:
for 1GR-FE ()
for 1UR-FE ()
for 3UR-FE ()
for 1VD-FTV ()

Measure the resistance according to the value(s) in the table below.

  • Standard Resistance:
  • Tester ConnectionConditionSpecified Condition
    2 (FS) - 1 (FE)Float level is F (upper)13.5 to 16.5 Ω
    Float level is E (lower)405.5 to 414.5 Ω
Text in Illustration
*1Component without harness connected
(Fuel Sender Gauge Assembly)
Result
ResultProceed to
OKA
NG (for 1GR-FE)B
NG (for 1UR-FE)C
NG (for 3UR-FE)D
NG (for 1VD-FTV)E
B
REPLACE FUEL SENDER GAUGE ASSEMBLY ()
C
REPLACE FUEL SENDER GAUGE ASSEMBLY ()
D
REPLACE FUEL SENDER GAUGE ASSEMBLY ()
E
REPLACE FUEL SENDER GAUGE ASSEMBLY ()
A
5.CHECK COMBINATION METER TYPE

Check the combination meter type

Result
ResultProceed to
w/ Multi-information DisplayA
w/o Multi-information DisplayB
B
REPLACE COMBINATION METER ASSEMBLY ()
A
REPLACE COMBINATION METER ASSEMBLY ()