Land Cruiser URJ200 URJ202 GRJ200 VDJ200 - HEATING / AIR CONDITIONING

DESCRIPTION

WIRING DIAGRAM

INSPECTION PROCEDURE

READ VALUE USING INTELLIGENT TESTER (AMBIENT TEMPERATURE SENSOR)

INSPECT AMBIENT TEMPERATURE SENSOR

CHECK HARNESS AND CONNECTOR (AMBIENT TEMPERATURE SENSOR - AIR CONDITIONING AMPLIFIER)

DTC B1412/12 Ambient Temperature Sensor Circuit

DESCRIPTION

The ambient temperature sensor is installed in the front part of the condenser to detect the ambient temperature and control the air conditioner "auto" mode. The sensor connected to the air conditioning amplifier assembly detects fluctuations in the ambient temperature. This data is used for controlling the room temperature. The sensor sends a signal to the air conditioning amplifier assembly. The resistance of the ambient temperature sensor changes in accordance with the ambient temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.


The air conditioning amplifier assembly applies voltage (5 V) to the ambient temperature sensor and reads voltage changes as the resistance of the ambient temperature sensor changes.

DTC CodeDTC Detection ConditionTrouble Area
B1412/12 An open or short in the ambient temperature sensor circuit.
Ambient temperature sensor
Harness or connector between ambient temperature sensor and air conditioning amplifier assembly
Air conditioning amplifier assembly

WIRING DIAGRAM

Dtc B1412/12  Ambient Temperature Sensor Circuit. HEATING / AIR CONDITIONING. Land Cruiser URJ200  URJ202 GRJ200 VDJ200

Dtc B1412/12  Ambient Temperature Sensor Circuit. HEATING / AIR CONDITIONING. Land Cruiser URJ200  URJ202 GRJ200 VDJ200

INSPECTION PROCEDURE

1.READ VALUE USING INTELLIGENT TESTER (AMBIENT TEMPERATURE SENSOR)

Use the Data List to check if the ambient temperature sensor is functioning properly.

Air Conditioner
Tester DisplayMeasurement Item/RangeNormal ConditionDiagnostic Note
Ambient Temp Sensor Ambient temperature sensor /
Min: -23.3°C (-9.94°F)
Max: 65.95°C (150.71°F)
Actual ambient temperature displayed Open in the circuit: -23.3°C (-9.94°F).
Short in the circuit: 65.95°C (150.71°F).
  • OK:
  • The display is as specified in the normal condition.
NG
Go to step 2
OK
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY ()
2.INSPECT AMBIENT TEMPERATURE SENSOR
Dtc B1412/12  Ambient Temperature Sensor Circuit. HEATING / AIR CONDITIONING. Land Cruiser URJ200  URJ202 GRJ200 VDJ200

Remove the ambient temperature sensor ().

Measure the resistance according to the value(s) in the table below.

  • Standard Resistance:
  • Tester ConnectionConditionSpecified Condition
    1 (+) - 2 (-)10°C (50°F)3.00 to 3.73 kΩ
    15°C (59°F)2.45 to 2.88 kΩ
    20°C (68°F)1.95 to 2.30 kΩ
    25°C (77°F)1.60 to 1.80 kΩ
    30°C (86°F)1.28 to 1.47 kΩ
    35°C (95°F)1.00 to 1.22 kΩ
    40°C (104°F)0.80 to 1.00 kΩ
    45°C (113°F)0.65 to 0.85 kΩ
    50°C (122°F)0.50 to 0.70 kΩ
    55°C (131°F)0.44 to 0.60 kΩ
    60°C (140°F)0.36 to 0.50 kΩ
  • NOTICE:
Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
When measuring, the sensor temperature must be the same as the ambient temperature.
  • HINT:
  • As the temperature increases, the resistance decreases (see the graph).
NG
REPLACE AMBIENT TEMPERATURE SENSOR ()
OK
3.CHECK HARNESS AND CONNECTOR (AMBIENT TEMPERATURE SENSOR - AIR CONDITIONING AMPLIFIER)
Dtc B1412/12  Ambient Temperature Sensor Circuit. HEATING / AIR CONDITIONING. Land Cruiser URJ200  URJ202 GRJ200 VDJ200

w/ Rear Heater


Disconnect the A14 sensor connector.

Disconnect the E35 amplifier connector.

Measure the resistance according to the value(s) in the table below.

  • Standard Resistance:
  • Tester ConnectionConditionSpecified Condition
    A14 (+) -1 - E35-10 (TAM)AlwaysBelow 1 Ω
    A14-2 (-) - E35-16 (SG-2)
    E35-10 (TAM) - Body groundAlways10 kΩ or higher
    E35-16 (SG-2) - Body ground
Dtc B1412/12  Ambient Temperature Sensor Circuit. HEATING / AIR CONDITIONING. Land Cruiser URJ200  URJ202 GRJ200 VDJ200

w/o Rear Heater


Disconnect the A14 sensor connector.

Disconnect the E81 amplifier connector.

Measure the resistance according to the value(s) in the table below.

  • Standard Resistance:
  • Tester ConnectionConditionSpecified Condition
    A14-1 (+) - E81-5 (TAM)AlwaysBelow 1 Ω
    A14-2 (-) - E81-13 (SG-2)
    E81-5 (TAM) - Body groundAlways10 kΩ or higher
    E81-13 (SG-2) - Body ground
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY ()