Land Cruiser URJ200 URJ202 GRJ200 VDJ200 - HEATING / AIR CONDITIONING


AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System) - DATA LIST / ACTIVE TEST

  • HINT:
  • Using the intelligent tester to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
  • NOTICE:
  • In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
DATA LIST

Connect the intelligent tester to the DLC3.

Turn the engine switch on (IG).

Turn the intelligent tester on.

Enter the following menus: Body / Air Conditioner / Data List.

Enter the following menus: Powertrain / Engine and ECT / Data List.

According to the display on the intelligent tester, read the Data List.

Air Conditioner
Tester DisplayMeasurement Item/RangeNormal ConditionDiagnostic Note
Room Temperature SensorFront room temperature sensor /
Min.: -6.5°C (20.3°F)
Max.: 57.25°C (135.05°F)
Actual room temperature for front seat displayedOpen in the circuit: -6.5°C (20.3°F).
Short in the circuit: 57.25°C (135.05°F).
Ambient Temp SensorAmbient temperature sensor /
Min.: -23.3°C (-9.94°F)
Max.: 65.95°C (150.71°F)
Actual ambient temperature displayedOpen in the circuit: -23.3°C (-9.94°F).
Short in the circuit: 65.95°C (150.71°F).
Adjusted Ambient TempAdjusted ambient temperature /
Min.: -30.8°C (-23.44°F)
Max.: 50.8°C (123.44°F)
Adjusted ambient temperature displayed-
Evaporator Fin ThermistorNo. 1 cooler thermistor /
Min.: -29.7°C (-21.46°F)
Max.: 59.55°C (139.19°F)
Actual evaporator temperature displayedOpen in the circuit: -29.7°C (-21.46°F).
Short in the circuit: 59.55°C (139.19°F).
Evaporator Target TempTarget evaporator temperature /
Min.: 1.5°C (34.7°F)
Max.: 4.0°C (39.2°F)
Target evaporator temperature displayed-
Solar Sensor (D Side)Driver side solar sensor /
Min.: 0, Max.: 255
Driver side solar sensor voltage increases as brightness increasesOpen in the circuit: 0
Short in the circuit: 255
Solar Sensor (P Side)Passenger side solar sensor /
Min.: 0, Max.: 255
Passenger side solar sensor voltage increases as brightness increasesOpen in the circuit: 0
Short in the circuit: 255
Engine Coolant TempEngine coolant temperature /
Min.: 1.3°C (34.34°F)
Max.: 90.55°C (194.99°F)
Actual engine coolant temperature displayed while engine warmed up-
Set Temperature (D Side)Driver side set temperature /
MAX COLD: 15.5°C (59.9°F)
MAX HOT: 32.5°C (90.5°F)
Driver side actual set temperature displayed-
Set Temperature (P Side)Passenger side set temperature /
MAX COLD: 15.5°C (59.9°F)
MAX HOT: 32.5°C (90.5°F)
Passenger side actual set temperature displayed-
A/M Servo Targ Pulse (Rear D)Rear air mix damper servo motor target pulse /
Min.: 9, Max.: 54 (for LHD)
Min.: 8, Max.: 53 (for RHD)
for LHD
MAX COOL: 9 (pulse)
MAX HOT: 54 (pulse)
for RHD
MAX COOL: 53 (pulse)
MAX HOT: 8 (pulse)
-
A/M Servo Targ Pulse (Rear P)Rear air mix damper servo motor (for front passenger side) target pulse /
Min.: 8, Max.: 53 (for LHD)
Min.: 9, Max.: 54 (for RHD)
for LHD
MAX COOL: 53 (pulse)
MAX HOT: 8 (pulse)
for RHD
MAX COOL: 9 (pulse)
MAX HOT: 54 (pulse)
-
Hand Free TelephoneHandsfree telephone / OFF or ONON: Handsfree telephone used
OFF: Handsfree telephone not used
-
Blower Motor Speed LevelBlower motor speed level /
Min.: 0 level,
Max.: 31 level
Increases in range between 0 and 31 as blower motor speed increases-
Regulator Pressure SensorRefrigerant pressure sensor /
Min.: -0.4566 MPaG
Max.: 3.2943 MPaG
Actual refrigerant pressure displayed-
Room Temp Sensor (Rear)Rear room temperature sensor /
Min.: -6.5°C (20.3°F)
Max.: 57.25°C (135.05°F)
Actual rear room temperature displayedOpen in the circuit: -6.5°C (20.3°F).
Short in the circuit: 57.25°C (135.05°F).
Ambient Temp Sens (Rear)No. 2 cooler thermistor /
Min.: -29.7°C (-21.46°F)
Max.: 59.55°C (139.19°F)
Actual rear evaporator temperature displayedOpen in the circuit: -29.7°C (-21.46°F).
Short in the circuit: 59.55°C (139.19°F).
Blower Motor Level (Rear)Rear blower motor speed level /
Min.: 0, Max.: 31
Increases in range between 0 to 31 as rear blower motor speed increases-
Air Mix Servo Targ Pulse(D)Air mix damper servo motor (for driver side) target pulse /
Min.: 8, Max.: 90 (for LHD)
Min.: 8, Max.: 90 (for RHD)
for LHD
MAX COOL: 90 (pulse)
MAX HOT: 8 (pulse)
for RHD
MAX COOL: 8 (pulse)
MAX HOT: 90 (pulse)
-
Air Mix Servo Targ Pulse(P)Air mix damper servo motor (for front passenger side) target pulse /
Min.: 8, Max.: 90 (for LHD)
Min.: 8, Max.: 90 (for RHD)
for LHD
MAX COOL: 8 (pulse)
MAX HOT: 90 (pulse)
for RHD
MAX COOL: 90 (pulse)
MAX HOT: 8 (pulse)
-
Air Inlet Damper Targ PulseREC/FRS damper servo motor target pulse /
Min.: 9, Max.: 37
for LHD
Recirculation: 37 (pulse)
Fresh: 9 (pulse)
for RHD
Recirculation: 9 (pulse)
Fresh: 37 (pulse)
-
Cool Air Bypass PulseCool air bypass damper servo motor target pulse /
Min.: 6, Max.: 57
Shut: 6 (pulse)
Open: 57 (pulse)
-
Electric Heater CountElectric heater count /
Min.: 0, Max.: 3
--
Shift Set TemperatureShift set temperature / +2 C, +1 C, NORMAL, -1 C, -2 CCustomized value displayed-
Air Inlet ModeAir inlet mode / AUTO, MANUALCustomized value displayed-
Compressor ModeCompressor mode / AUTO, MANUALCustomized value displayed-
Compressor/DEF ModeCompressor/DEF mode / LINK, NORMALCustomized value displayed-
Evaporator ControlEvaporator control / AUTO, MANUALCustomized value displayed-
Button Press BuzzerButton press buzzer / ON or OFFCustomized value displayed-
Foot/DEF Auto ModeFOOT/DEF auto mode / ON or OFFCustomized value displayed-
Foot/DEF Auto Blow UpFOOT/DEF auto blower up function / ON or OFFCustomized value displayed-
Filter SensorFilter sensor / LESS, NORMAL, MORECustomized value displayed-
Rear A/P HI SetRear A/P HI set / ON or OFFCustomized value displayed-
Ambient Temperature ShiftAmbient temperature shift / +3 C, +2 C, +1 C, NORMAL, -1 C, -2 C, -3 CCustomized value displayed-
A/O Damper FACE Pos(D)Air outlet damper servo motor (for driver side mode) target pulse /
Min.: 6, Max.: 117
FACE1: 117 (pulse)
FACE2: 109 (pulse)
B/L1: 93 (pulse)
B/L2: 81 (pulse)
FOOT-F: 41 (pulse)
FOOT-R: 41 (pulse)
FOOT-D: 52 (pulse)
F/D: 18 (pulse)
DEF: 6 (pulse)
-
A/O Damper FACE Pos(P)Air outlet damper servo motor (for front passenger side mode) target pulse /
Min.: 6, Max.: 117 (for LHD)
Min.: 9, Max.: 120 (for RHD)
for LHD
FACE1: 117 (pulse)
FACE2: 109 (pulse)
B/L1: 93 (pulse)
B/L2: 81 (pulse)
FOOT-F: 41 (pulse)
FOOT-R: 41 (pulse)
FOOT-D: 52 (pulse)
F/D: 18 (pulse)
DEF: 6 (pulse)
for RHD
FACE1: 9 (pulse)
FACE2: 17 (pulse)
B/L1: 33 (pulse)
B/L2: 45 (pulse)
FOOT-F: 85 (pulse)
FOOT-R: 85 (pulse)
FOOT-D: 74 (pulse)
F/D: 108 (pulse)
DEF: 120 (pulse)
-
Air Mix Servo Targ Pls(F&R D)Front air mix damper servo motor (for driver side rear air flow) target pulse /
Min.: 13, Max.: 41 (for LHD)
Min.: 5, Max.: 33 (for RHD)
for LHD
MAX COOL: 13 (pulse)
MAX HOT: 41 (pulse)
for RHD
MAX COOL: 33 (pulse)
MAX HOT: 5 (pulse)
-
Air Mix Servo Targ Pls(F&R P)Front air mix damper servo motor (for front passenger side rear air flow) target pulse /
Min.: 5, Max.: 33 (for LHD)
Min.: 13, Max.: 41 (for RHD)
for LHD
MAX COOL: 33 (pulse)
MAX HOT: 5 (pulse)
for RHD
MAX COOL: 13 (pulse)
MAX HOT: 41 (pulse)
-
Air Outlet Servo Pls (F&R D)Air outlet damper servo motor (for rear seat mode) target pulse /
Min.: 9, Max.: 79
FACE1: 9 (pulse)
B/L1: 28 (pulse)
FOOT-O: 41 (pulse)
F/D: 67 (pulse)
DEF: 79 (pulse)
-
Air Outlet Servo Pulse (R)Rear air outlet damper servo motor target pulse /
Min.: 7, Max.: 83
FOOT: 7 (pulse)
B/L: 42 (pulse)
FACE: 83 (pulse)
-
Room Temperature Sensor (RP)Rear room temperature sensor /
Min.: -6.5°C (20.3°F)
Max.: 57.25°C (135.05°F)
Actual rear room temperature displayedOpen in the circuit: -6.5°C (20.3°F)
Short in the circuit: 57.25°C (135.05°F)
Set Temperature (Rear D side)Rear driver side set temperature /
MAX COLD: 0°C (32°F)
MAX HOT: 32°C (54°F)
Rear driver side actual set temperature displayed-
Set Temperature (Rear P side)Rear passenger side set temperature /
MAX COLD: 0°C (32°F)
MAX HOT: 32°C (54°F)
Rear passenger side actual set temperature displayed-
Foot Duct Sensor(Rear D)Min.: -12.7°C (9.14°F)
Max.: 76.55°C (169.79°F)
Actual air duct temperature sensor (for driver side) displayedOpen in the circuit: -12.7°C (9.14°F)
Short in the circuit: 76.55°C (169.79°F)
Foot Duct Sensor(Rear P)Min.: -12.7°C (9.14°F)
Max.: 76.55°C (169.79°F)
Actual air duct temperature sensor (for passenger side) displayedOpen in the circuit: -12.7°C (9.14°F)
Short in the circuit: 76.55°C (169.79°F)
Number of Trouble CodesNumber of trouble codes /
Min.: 0, Max.: 255
Number of DTCs displayed-
A/O Damper FOOT/DEF Pos(P)Air outlet damper servo motor (for DEF mode) target pulse /
Min.: 6, Max.: 117
FACE1: 117 (pulse)
FACE2: 109 (pulse)
B/L1: 93 (pulse)
B/L2: 81 (pulse)
FOOT-D: 52 (pulse)
FOOT-R: 41 (pulse)
FOOT-F: 41 (pulse)
F/D: 18 (pulse)
DEF: 6 (pulse)
-
Engine
Tester DisplayMeasurement Item/RangeNormal ConditionDiagnostic Note
A/C SignalA/C signal / ON or OFFON: A/C Switch on
OFF: A/C Switch off
-
ACTIVE TEST
  • HINT:
  • Using the intelligent tester to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.

Connect the intelligent tester to the DLC3.

Turn the engine switch on (IG).

Turn the intelligent tester on.

Enter the following menus: Body / Air Conditioner / Active Test.

According to the display on the intelligent tester, perform the Active Test.

Tester DisplayTest PartControl RangeDiagnostic Note
Blower MotorFront blower motorMin.: 0, Max.: 31-
Magnetic Clutch RelayMagnetic clutch relayOFF or ON-
Air Mix Servo Targ Pulse(D)Air mix servo motor pulse (Front A/C D side)Min.: 8, Max.: 90-
Air Mix Servo Targ Pulse(P)Air mix servo motor pulse (Front A/C P side)Min.: 8, Max.: 90-
Air Inlet Damper Targ PulseAir inlet damper target pulseMin.: 9, Max.: 37-
Cool Air Bypass PulseDriver side cool air bypass pulseMin.: 6, Max.: 57-
Rear Blower MotorRear blower motorMin.: 0, Max.: 31-
Rear Air Mix Servo Targ PulseRear air mix damper servo motor pulsefor LHD
Min.: 9, Max.: 54
for RHD
Min.: 8, Max.: 53
-
DEF A/O Servo Pulse(D)Rear air outlet damper servo motor pulseMin.: 7, Max.: 83-
Rear A/M Servo Pulse(P)Rear air mix damper servo motor (for front passenger side) pulsefor LHD
Min.: 8, Max.: 53
for RHD
Min.: 9, Max.: 54
-
Rear A/C Mag ValveRear A/C magnetic valveOFF or ON-
Face A/O Servo Pulse(D)Air outlet servo motor pulse (D side)Min.: 6, Max.: 117-
Face A/O Servo Pulse(P)Air outlet servo motor pulse (P side)for LHD
Min.: 6, Max.: 117
for RHD
Min.: 9, Max.: 120
-
A/M Servo Puls(F&R D)Air mix servo motor pulse (Front A/C rear air flow D side)for LHD
Min.: 9, Max.: 54
for RHD
Min.: 8, Max.: 53
-
A/M Servo Puls(F&R P)Air mix servo motor pulse (Front A/C rear air flow P side)for LHD
Min.: 8, Max.: 53
for RHD
Min.: 9, Max.: 54
-
A/O Servo Pulse(F&R D)Air outlet servo motor pulse (Front A/C rear air flow D side)Min.: 9, Max.: 79-
A/O Servo Pulse(Rr D)Air outlet servo motor pulse (Rr D side)Min.: 7, Max.: 83-