Land Cruiser URJ200 URJ202 GRJ200 VDJ200 - HEATING / AIR CONDITIONING
AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System) - DATA LIST / ACTIVE TEST
- HINT:
- Using the intelligent tester to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
- NOTICE:
- In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
DATA LIST |
Connect the intelligent tester to the DLC3.
Turn the engine switch on (IG).
Turn the intelligent tester on.
Enter the following menus: Body / Air Conditioner / Data List.
Enter the following menus: Powertrain / Engine and ECT / Data List.
According to the display on the intelligent tester, read the Data List.
Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
Room Temperature Sensor | Front room temperature sensor / Min.: -6.5°C (20.3°F) Max.: 57.25°C (135.05°F) | Actual room temperature for front seat displayed | Open in the circuit: -6.5°C (20.3°F). Short in the circuit: 57.25°C (135.05°F). |
Ambient Temp Sensor | Ambient temperature sensor / Min.: -23.3°C (-9.94°F) Max.: 65.95°C (150.71°F) | Actual ambient temperature displayed | Open in the circuit: -23.3°C (-9.94°F). Short in the circuit: 65.95°C (150.71°F). |
Adjusted Ambient Temp | Adjusted ambient temperature / Min.: -30.8°C (-23.44°F) Max.: 50.8°C (123.44°F) | Adjusted ambient temperature displayed | - |
Evaporator Fin Thermistor | No. 1 cooler thermistor / Min.: -29.7°C (-21.46°F) Max.: 59.55°C (139.19°F) | Actual evaporator temperature displayed | Open in the circuit: -29.7°C (-21.46°F). Short in the circuit: 59.55°C (139.19°F). |
Evaporator Target Temp | Target evaporator temperature / Min.: 1.5°C (34.7°F) Max.: 4.0°C (39.2°F) | Target evaporator temperature displayed | - |
Solar Sensor (D Side) | Driver side solar sensor / Min.: 0, Max.: 255 | Driver side solar sensor voltage increases as brightness increases | Open in the circuit: 0 Short in the circuit: 255 |
Solar Sensor (P Side) | Passenger side solar sensor / Min.: 0, Max.: 255 | Passenger side solar sensor voltage increases as brightness increases | Open in the circuit: 0 Short in the circuit: 255 |
Engine Coolant Temp | Engine coolant temperature / Min.: 1.3°C (34.34°F) Max.: 90.55°C (194.99°F) | Actual engine coolant temperature displayed while engine warmed up | - |
Set Temperature (D Side) | Driver side set temperature / MAX COLD: 15.5°C (59.9°F) MAX HOT: 32.5°C (90.5°F) | Driver side actual set temperature displayed | - |
Set Temperature (P Side) | Passenger side set temperature / MAX COLD: 15.5°C (59.9°F) MAX HOT: 32.5°C (90.5°F) | Passenger side actual set temperature displayed | - |
A/M Servo Targ Pulse (Rear D) | Rear air mix damper servo motor target pulse / Min.: 9, Max.: 54 (for LHD) Min.: 8, Max.: 53 (for RHD) | for LHD MAX COOL: 9 (pulse) MAX HOT: 54 (pulse) MAX COOL: 53 (pulse) MAX HOT: 8 (pulse) | - |
A/M Servo Targ Pulse (Rear P) | Rear air mix damper servo motor (for front passenger side) target pulse / Min.: 8, Max.: 53 (for LHD) Min.: 9, Max.: 54 (for RHD) | for LHD MAX COOL: 53 (pulse) MAX HOT: 8 (pulse) MAX COOL: 9 (pulse) MAX HOT: 54 (pulse) | - |
Hand Free Telephone | Handsfree telephone / OFF or ON | ON: Handsfree telephone used OFF: Handsfree telephone not used | - |
Blower Motor Speed Level | Blower motor speed level / Min.: 0 level, Max.: 31 level | Increases in range between 0 and 31 as blower motor speed increases | - |
Regulator Pressure Sensor | Refrigerant pressure sensor / Min.: -0.4566 MPaG Max.: 3.2943 MPaG | Actual refrigerant pressure displayed | - |
Room Temp Sensor (Rear) | Rear room temperature sensor / Min.: -6.5°C (20.3°F) Max.: 57.25°C (135.05°F) | Actual rear room temperature displayed | Open in the circuit: -6.5°C (20.3°F). Short in the circuit: 57.25°C (135.05°F). |
Ambient Temp Sens (Rear) | No. 2 cooler thermistor / Min.: -29.7°C (-21.46°F) Max.: 59.55°C (139.19°F) | Actual rear evaporator temperature displayed | Open in the circuit: -29.7°C (-21.46°F). Short in the circuit: 59.55°C (139.19°F). |
Blower Motor Level (Rear) | Rear blower motor speed level / Min.: 0, Max.: 31 | Increases in range between 0 to 31 as rear blower motor speed increases | - |
Air Mix Servo Targ Pulse(D) | Air mix damper servo motor (for driver side) target pulse / Min.: 8, Max.: 90 (for LHD) Min.: 8, Max.: 90 (for RHD) | for LHD MAX COOL: 90 (pulse) MAX HOT: 8 (pulse) MAX COOL: 8 (pulse) MAX HOT: 90 (pulse) | - |
Air Mix Servo Targ Pulse(P) | Air mix damper servo motor (for front passenger side) target pulse / Min.: 8, Max.: 90 (for LHD) Min.: 8, Max.: 90 (for RHD) | for LHD MAX COOL: 8 (pulse) MAX HOT: 90 (pulse) MAX COOL: 90 (pulse) MAX HOT: 8 (pulse) | - |
Air Inlet Damper Targ Pulse | REC/FRS damper servo motor target pulse / Min.: 9, Max.: 37 | for LHD Recirculation: 37 (pulse) Fresh: 9 (pulse) for RHD Recirculation: 9 (pulse) Fresh: 37 (pulse) | - |
Cool Air Bypass Pulse | Cool air bypass damper servo motor target pulse / Min.: 6, Max.: 57 | Shut: 6 (pulse) Open: 57 (pulse) | - |
Electric Heater Count | Electric heater count / Min.: 0, Max.: 3 | - | - |
Shift Set Temperature | Shift set temperature / +2 C, +1 C, NORMAL, -1 C, -2 C | Customized value displayed | - |
Air Inlet Mode | Air inlet mode / AUTO, MANUAL | Customized value displayed | - |
Compressor Mode | Compressor mode / AUTO, MANUAL | Customized value displayed | - |
Compressor/DEF Mode | Compressor/DEF mode / LINK, NORMAL | Customized value displayed | - |
Evaporator Control | Evaporator control / AUTO, MANUAL | Customized value displayed | - |
Button Press Buzzer | Button press buzzer / ON or OFF | Customized value displayed | - |
Foot/DEF Auto Mode | FOOT/DEF auto mode / ON or OFF | Customized value displayed | - |
Foot/DEF Auto Blow Up | FOOT/DEF auto blower up function / ON or OFF | Customized value displayed | - |
Filter Sensor | Filter sensor / LESS, NORMAL, MORE | Customized value displayed | - |
Rear A/P HI Set | Rear A/P HI set / ON or OFF | Customized value displayed | - |
Ambient Temperature Shift | Ambient temperature shift / +3 C, +2 C, +1 C, NORMAL, -1 C, -2 C, -3 C | Customized value displayed | - |
A/O Damper FACE Pos(D) | Air outlet damper servo motor (for driver side mode) target pulse / Min.: 6, Max.: 117 | FACE1: 117 (pulse) FACE2: 109 (pulse) B/L1: 93 (pulse) B/L2: 81 (pulse) FOOT-F: 41 (pulse) FOOT-R: 41 (pulse) FOOT-D: 52 (pulse) F/D: 18 (pulse) DEF: 6 (pulse) | - |
A/O Damper FACE Pos(P) | Air outlet damper servo motor (for front passenger side mode) target pulse / Min.: 6, Max.: 117 (for LHD) Min.: 9, Max.: 120 (for RHD) | for LHD FACE1: 117 (pulse) FACE2: 109 (pulse) B/L1: 93 (pulse) B/L2: 81 (pulse) FOOT-F: 41 (pulse) FOOT-R: 41 (pulse) FOOT-D: 52 (pulse) F/D: 18 (pulse) DEF: 6 (pulse) FACE1: 9 (pulse) FACE2: 17 (pulse) B/L1: 33 (pulse) B/L2: 45 (pulse) FOOT-F: 85 (pulse) FOOT-R: 85 (pulse) FOOT-D: 74 (pulse) F/D: 108 (pulse) DEF: 120 (pulse) | - |
Air Mix Servo Targ Pls(F&R D) | Front air mix damper servo motor (for driver side rear air flow) target pulse / Min.: 13, Max.: 41 (for LHD) Min.: 5, Max.: 33 (for RHD) | for LHD MAX COOL: 13 (pulse) MAX HOT: 41 (pulse) MAX COOL: 33 (pulse) MAX HOT: 5 (pulse) | - |
Air Mix Servo Targ Pls(F&R P) | Front air mix damper servo motor (for front passenger side rear air flow) target pulse / Min.: 5, Max.: 33 (for LHD) Min.: 13, Max.: 41 (for RHD) | for LHD MAX COOL: 33 (pulse) MAX HOT: 5 (pulse) MAX COOL: 13 (pulse) MAX HOT: 41 (pulse) | - |
Air Outlet Servo Pls (F&R D) | Air outlet damper servo motor (for rear seat mode) target pulse / Min.: 9, Max.: 79 | FACE1: 9 (pulse) B/L1: 28 (pulse) FOOT-O: 41 (pulse) F/D: 67 (pulse) DEF: 79 (pulse) | - |
Air Outlet Servo Pulse (R) | Rear air outlet damper servo motor target pulse / Min.: 7, Max.: 83 | FOOT: 7 (pulse) B/L: 42 (pulse) FACE: 83 (pulse) | - |
Room Temperature Sensor (RP) | Rear room temperature sensor / Min.: -6.5°C (20.3°F) Max.: 57.25°C (135.05°F) | Actual rear room temperature displayed | Open in the circuit: -6.5°C (20.3°F) Short in the circuit: 57.25°C (135.05°F) |
Set Temperature (Rear D side) | Rear driver side set temperature / MAX COLD: 0°C (32°F) MAX HOT: 32°C (54°F) | Rear driver side actual set temperature displayed | - |
Set Temperature (Rear P side) | Rear passenger side set temperature / MAX COLD: 0°C (32°F) MAX HOT: 32°C (54°F) | Rear passenger side actual set temperature displayed | - |
Foot Duct Sensor(Rear D) | Min.: -12.7°C (9.14°F) Max.: 76.55°C (169.79°F) | Actual air duct temperature sensor (for driver side) displayed | Open in the circuit: -12.7°C (9.14°F) Short in the circuit: 76.55°C (169.79°F) |
Foot Duct Sensor(Rear P) | Min.: -12.7°C (9.14°F) Max.: 76.55°C (169.79°F) | Actual air duct temperature sensor (for passenger side) displayed | Open in the circuit: -12.7°C (9.14°F) Short in the circuit: 76.55°C (169.79°F) |
Number of Trouble Codes | Number of trouble codes / Min.: 0, Max.: 255 | Number of DTCs displayed | - |
A/O Damper FOOT/DEF Pos(P) | Air outlet damper servo motor (for DEF mode) target pulse / Min.: 6, Max.: 117 | FACE1: 117 (pulse) FACE2: 109 (pulse) B/L1: 93 (pulse) B/L2: 81 (pulse) FOOT-D: 52 (pulse) FOOT-R: 41 (pulse) FOOT-F: 41 (pulse) F/D: 18 (pulse) DEF: 6 (pulse) | - |
Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
A/C Signal | A/C signal / ON or OFF | ON: A/C Switch on OFF: A/C Switch off | - |
ACTIVE TEST |
- HINT:
- Using the intelligent tester to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.
Connect the intelligent tester to the DLC3.
Turn the engine switch on (IG).
Turn the intelligent tester on.
Enter the following menus: Body / Air Conditioner / Active Test.
According to the display on the intelligent tester, perform the Active Test.
Tester Display | Test Part | Control Range | Diagnostic Note |
Blower Motor | Front blower motor | Min.: 0, Max.: 31 | - |
Magnetic Clutch Relay | Magnetic clutch relay | OFF or ON | - |
Air Mix Servo Targ Pulse(D) | Air mix servo motor pulse (Front A/C D side) | Min.: 8, Max.: 90 | - |
Air Mix Servo Targ Pulse(P) | Air mix servo motor pulse (Front A/C P side) | Min.: 8, Max.: 90 | - |
Air Inlet Damper Targ Pulse | Air inlet damper target pulse | Min.: 9, Max.: 37 | - |
Cool Air Bypass Pulse | Driver side cool air bypass pulse | Min.: 6, Max.: 57 | - |
Rear Blower Motor | Rear blower motor | Min.: 0, Max.: 31 | - |
Rear Air Mix Servo Targ Pulse | Rear air mix damper servo motor pulse | for LHD Min.: 9, Max.: 54 for RHD Min.: 8, Max.: 53 | - |
DEF A/O Servo Pulse(D) | Rear air outlet damper servo motor pulse | Min.: 7, Max.: 83 | - |
Rear A/M Servo Pulse(P) | Rear air mix damper servo motor (for front passenger side) pulse | for LHD Min.: 8, Max.: 53 for RHD Min.: 9, Max.: 54 | - |
Rear A/C Mag Valve | Rear A/C magnetic valve | OFF or ON | - |
Face A/O Servo Pulse(D) | Air outlet servo motor pulse (D side) | Min.: 6, Max.: 117 | - |
Face A/O Servo Pulse(P) | Air outlet servo motor pulse (P side) | for LHD Min.: 6, Max.: 117 for RHD Min.: 9, Max.: 120 | - |
A/M Servo Puls(F&R D) | Air mix servo motor pulse (Front A/C rear air flow D side) | for LHD Min.: 9, Max.: 54 for RHD Min.: 8, Max.: 53 | - |
A/M Servo Puls(F&R P) | Air mix servo motor pulse (Front A/C rear air flow P side) | for LHD Min.: 8, Max.: 53 for RHD Min.: 9, Max.: 54 | - |
A/O Servo Pulse(F&R D) | Air outlet servo motor pulse (Front A/C rear air flow D side) | Min.: 9, Max.: 79 | - |
A/O Servo Pulse(Rr D) | Air outlet servo motor pulse (Rr D side) | Min.: 7, Max.: 83 | - |