Land Cruiser URJ200 URJ202 GRJ200 VDJ200 - WINDOW / GLASS

DESCRIPTION

INSPECTION PROCEDURE

CHECK BASIC FUNCTION (WIRELESS DOOR LOCK CONTROL SYSTEM AND POWER DOOR LOCK CONTROL SYSTEM)

CHECK MANUAL UP/DOWN FUNCTION

CHECK REMOTE UP/DOWN FUNCTION

POWER WINDOW CONTROL SYSTEM (for Models with Jam Protection Function on 4 Windows) - All Power Windows do not Operate with Driver Side Door Key Cylinder or Wireless Transmitter

DESCRIPTION

When a transmitter switch is pushed, the following occurs: 1) the door control receiver receives the transmitter signal; 2) the door control receiver sends a signal to the main body ECU; 3) the main body ECU sends the operation permission signal to the power window regulator motors; and 4) the power window motors are activated.
When the driver door key cylinder (key linked switch) is turned, the following occurs: 1) the door lock motor receives the signal; 2) the door lock motor sends the signal to the main body ECU; 3) the main body ECU sends the signal to the power window regulator motors; and 4) the power window motors are activated.

INSPECTION PROCEDURE

1.CHECK BASIC FUNCTION (WIRELESS DOOR LOCK CONTROL SYSTEM AND POWER DOOR LOCK CONTROL SYSTEM)

Check that all the doors can be locked and unlocked with the wireless transmitter and the driver side door key cylinder (key linked switch).

Result
ResultProceed to
All doors can be locked and unlocked with transmitter and driver side door key cylinderA
All doors cannot be locked and unlocked with transmitter (w/ Entry and Start System)B
All doors cannot be locked and unlocked with transmitter (w/o Entry and Start System)C
All doors cannot be locked and unlocked with driver side door key cylinderD
B
GO TO WIRELESS DOOR LOCK CONTROL SYSTEM ()
C
GO TO WIRELESS DOOR LOCK CONTROL SYSTEM ()
D
GO TO POWER DOOR LOCK CONTROL SYSTEM ()
A
2.CHECK MANUAL UP/DOWN FUNCTION

Check that all the power windows move when the manual up/down function of the master switch and regulator switch is operated ().

  • OK:
  • All power windows move.
NG
OTHER PROBLEM (GO TO PROBLEM SYMPTOMS TABLE) ()
OK
3.CHECK REMOTE UP/DOWN FUNCTION

Check that all the power windows move when the remote up/down function of the master switch is operated ().

  • OK:
  • All power windows move.
NG
OTHER PROBLEM (GO TO PROBLEM SYMPTOMS TABLE) ()
OK
REPLACE MAIN BODY ECU (COWL SIDE JUNCTION BLOCK LH)