Land Cruiser URJ200 URJ202 GRJ200 VDJ200 - STEERING COLUMN


HEATED STEERING WHEEL SYSTEM - FAIL-SAFE CHART

MALFUNCTION DETECTION

Operation when malfunction is detected

ContentOperation
When thermistor trouble is detectedHeater off
When overheating (175°C (347°F)) of controller is detectedHeater off
When load short current (50 A or more) is detectedHeater off
When undervoltage (4.5 V) is detectedHeater off
OFF timer (30 min.)After preset time of timer passes, heater off
Reverse voltage protectionProtection circuit operates

Malfunction detection conditions

When an open or short in the steering wheel thermistor continues for 2 seconds or more.

When the steering heater switch momentary switch is pressed continuously for 10 seconds or more.

Malfunction display

The LED of the steering heater switch blinks at 0.3 second intervals.

Restore condition

If the normal condition is restored for 2 seconds or more, the previous operation before the malfunction occurred continues. However, regardless of if a malfunction is detected and the malfunction operation is occurring, and regardless of if the normal condition is restored and the system is operating normally, the timer will turn off the heater 30 minutes after the switch was first turned on.