Land Cruiser URJ200 URJ202 GRJ200 VDJ200 - 1GR-FE STARTING

STARTER - INSTALLATION

1. INSTALL FLYWHEEL HOUSING SIDE COVER
2. INSTALL STARTER ASSEMBLY

Install the starter with the 2 bolts.

  • Torque:
  • 37 N*m{ 377 kgf*cm, 27 ft.*lbf}

Connect the starter wire with the nut.

  • Torque:
  • 9.8 N*m{ 100 kgf*cm, 87 in.*lbf}

Connect the terminal cap.

Connect the starter connector.

Connect the ground wire with the bolt.

  • Torque:
  • 13 N*m{ 130 kgf*cm, 9 ft.*lbf}
3. INSTALL STARTER COVER

Install the starter cover with the 3 bolts.

  • Torque:
  • 12 N*m{ 117 kgf*cm, 8 ft.*lbf}
4. INSTALL EXHAUST MANIFOLD SUB-ASSEMBLY LH

()


5. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
  • NOTICE:
  • When disconnecting the cable, some systems need to be initialized after the cable is reconnected ().