Land Cruiser URJ200 URJ202 GRJ200 VDJ200 - 1GR-FE ENGINE CONTROL

CAMSHAFT OIL CONTROL VALVE - INSPECTION

1. INSPECT CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLY

Measure the resistance according to the value(s) in the table below.

  • Standard Resistance:
  • Tester ConnectionConditionSpecified Condition
    1 - 220°C (68°F)6.9 to 7.9 Ω

If the result is not as specified, replace the camshaft timing oil control valve.


Camshaft Oil Control Valve - Inspection. 1GR-FE ENGINE CONTROL. Land Cruiser URJ200  URJ202 GRJ200 VDJ200

Connect the positive (+) lead of the battery to terminal 1 and the negative (-) lead to terminal 2 and check the movement of the valve.

  • OK:
  • Tester ConnectionConditionSpecified Condition
    1 - 2Battery positive (+) voltage is appliedValve moves in direction of left arrow shown in illustration
    Battery positive (+) voltage is cut offValve moves in direction of right arrow shown in illustration
Text in Illustration
*aComponent without harness connected
(Camshaft Timing Oil Control Valve)

If the result is not as specified, replace the camshaft timing oil control valve.


If the valve cannot return properly because of foreign matter, a small pressure leak in the advanced direction may occur and a DTC may be stored.